Section 2 Operation
Section 2 Operation
2.1 Prestart Checklist
To ensure continued satisfactory operation perform the
following checks or inspections before or at each
startup, as designated, and at the intervals specified in
the service schedule. In addition, some checks require
verification after the unit starts.
Air Inlets.
Check for clean and unobstructed air inlets.
Air Shrouding.
Check for securely installed and
positioned air shrouding.
Backfire Flame Arrester.
Check for a clean and
installed backfire flame arrester to prevent unfiltered air
from entering the engine.
Battery.
Check for tight battery connections. Consult
the battery manufacturer’s instructions regarding
battery care and maintenance.
Coolant Level.
Check the coolant level according to the
cooling system maintenance information.
Exhaust System.
Check for exhaust leaks and
blockages. Check the silencer and piping condition and
check for tight exhaust system connections.
Inspect the exhaust system components (exhaust
manifold, catalyst, exhaust hose, hose clamps, silencer,
and outlet flapper) for cracks, leaks, and corrosion.
D
Check the hoses for softness, cracks, leaks, or dents.
Replace the hoses as needed.
D
Check for corroded or broken metal parts and replace
them as needed.
D
Check for loose, corroded, or missing clamps.
Tighten or replace the hose clamps and/or hangers as
needed.
D
Check that the exhaust outlet is unobstructed.
D
Visually inspect for exhaust leaks
(blowby)
. Check
for carbon or soot residue on exhaust components.
Carbon and soot residue indicates an exhaust leak.
Seal leaks as needed.
D
Ensure that the carbon monoxide detector(s) is (1) in
the craft, (2) functional, and (3) energized whenever
the generator set operates.
For your safety: Never operate the generator set
without a functioning carbon
monoxide detector(s) for your
safety and the safety of others on
your vessel.
Fuel Level.
Check the fuel level and keep the tank(s)
full to ensure adequate fuel supply.
Oil Level.
Maintain the oil level at or near, not over, the
full mark on the dipstick.
Operating Area.
Check for obstructions that could
block the flow of cooling air. Keep the air intake area
clean. Do not leave rags, tools, or debris on or near the
generator set.
Seawater Pump Priming.
Prime the seawater pump
before initial startup. To prime the pump: (1) close the
seacock, (2) remove the hose from the water-filter
outlet, (3) fill the hose and seawater pump with clean
water, (4) reconnect the hose to the water filter outlet,
and (5) open the seacock. Confirm seawater pump
operation on startup as indicated by water discharge
from the exhaust outlet.
2.2 Marine Inspection
Kohler Co. recommends that all boat owners have their
vessels inspected at the start of each boating season by
the US Coast Guard, the local Coast Guard Auxiliary, or
local state agency.
Kohler Co. also recommends having the generator’s
exhaust system inspected at the start of each boating
season by an authorized Kohler
r
distributor/dealer.
Repair any problems identified before operating the
generator set.
Carbon monoxide.
Can
cause
severe
nausea,
fainting, or death.
The exhaust system must be
leakproof and routinely inspected.
WARNING
Содержание 10EKD-Low CO
Страница 4: ...TP 6591 10 13 4 Notes...
Страница 8: ...TP 6591 10 13 8 Safety Precautions and Instructions Notes...
Страница 12: ...TP 6591 10 13 12 Section 1 Service Views Notes...
Страница 42: ...TP 6591 10 13 42 Section 5 Wiring Diagrams GM90655A Figure 5 1 Point to Point Wiring Diagram Sheet 1 of 2...
Страница 43: ...TP 6591 10 13 43 Section 5 Wiring Diagrams GM90655B Figure 5 2 Point to Point Wiring Diagram Sheet 2 of 2...
Страница 44: ...TP 6591 10 13 44 Section 5 Wiring Diagrams ADV8631A Figure 5 3 Schematic Wiring Diagram Sheet 1 of 1...
Страница 48: ...TP 6591 10 13 48 Notes...
Страница 49: ...TP 6591 10 13 49 Notes...
Страница 50: ...TP 6591 10 13 50 Notes...
Страница 51: ...TP 6591 10 13 51 Notes...