Safety Precautions (EP Sensor)

Before selecting and using the product, please read all the Safety Precautions carefully to ensure proper product use.
The Safety Precautions shown below are to help you use the product safely and correctly, and to prevent injury or damage to you, other
people, and assets beforehand.

This product was designed and manufactured as parts for use in General Industrial Machinery.

In the selection and handling of the equipment, the system designer or other person with fully adequate knowledge and experience should
always read the Safety Precautions, Catalog, Owner’s Manual and other literature before commencing operation. Making mistakes in handling
is dangerous.

The customer should take responsibility to verify that the product is compatible with the customer’s systems. Use the product based on your good
judgment.

After reading the Owner’s Manual, Catalog, etc., always place them where they can be easily available for reference to users of this product.

If transferring or lending the product to another person, always attach the Owner’s Manual, Catalog, etc., to the product where they are easily
visible, to ensure that the new user can use the product safely and properly.

The danger, warning, and caution items listed under these “Safety Precautions” do not cover all possible cases. Read the Catalog and
Owner’s Manual carefully, and always keep safety first.

Do not use the product for the purposes listed below:
1. Medical equipment related to maintenance or management of

human lives or bodies.

2. Mechanical devices or equipment designed for the purpose of

moving or transporting people.

3. Critical safety components in mechanical devices.
This product has not been planned or designed for purposes that require
advanced stages of safety. It could cause injury to human life.

Do not use the product in locations with or near dangerous
substances such as flammable or ignitable substances.
It could ignite or burst into flames.

When mounting the product and workpiece, always firmly support and
secure them in place. Dropping or falling the product or improper
operation could result in injury.

Persons who use a pacemaker, etc., should keep a distance of at
least 1 meter away from the product. There is a possibility that the
pacemaker will malfunction due to the strong magnet built into the
product.

Never attempt to remodel the product. It could result in abnormal
operation leading to injury, electric shock, fire, etc.

Never attempt inappropriate disassembly, or assembly of the product
relating to its basic inner construction, or to its performance or
functions. It could result in injury, electric shock, fire, etc.

Do not splash water on the product. Spraying it with water, washing it,
or using it underwater could result in malfunction of the product
leading to injury, electric shock, fire, etc.

When wiring is completed, check that there are no errors in the wiring
connections before switching on the power.

Correctly apply the specified voltage to the EP Sensor and EP
Monitor. Applying of the wrong voltage will prevent the equipment
from performing its specified functions, and may result in damage or
burnout of the product itself.

Do not insert or pull out the connector while the device is powered on.
Also, do not apply unnecessary stress to the connector. It could result
in erratic operation of the equipment leading to personal injury,
damage to equipment, or electric shock, etc.

Do not touch the terminals and the miscellaneous switches, etc., while
the device is powered on. There is a possibility of electric shock and
abnormal operation.

Avoid scratching the cords of cables, etc.
Letting the cords be subject to scratching, excessive bending, pulling,
rolling up, or being placed under heavy objects or squeezed between
two objects, may result in current leaks or defective continuity that
could lead to fire, electric shock, or abnormal operation.

Do not throw the product into fire.
The product could explode and/or release toxic gases.

Do not sit on the product, place your foot on it, or place other objects
on it.
Accidents such as falling could result in injury. Dropping or toppling
the product may result in injury, or it might also damage or break it,
resulting in abnormal or erratic operation, runaway, etc.

For inspection, maintenance, replacement, or other kinds of
operations related to the product, always completely turn off the
power supply before beginning.

Do not use the product in excess of its specification range. Such use
could result in product breakdowns, function stop, damage, or
drastically reduce the operating life.

If using the product in the locations listed below, implement adequate
shielding measures.
Failure to take these measures may cause erratic operation and lead
to equipment damage and/or injuries:
1. Locations subject to large electric current or magnetic fields
2. Locations with the possibility of exposure to radiation

Design safety circuits and equipment systems so as to avoid
equipment damage or personal injury when the machine is shut down
due to an emergency stop, power outages, or other system
abnormalities.

Do not use the same conduit or parallel wiring with power lines and
high voltage lines. The resulting noise may lead to erratic operation of
the EP Sensor and EP Monitor.

Always shut off the power supply when performing wiring work. There
is a possibility of electric shock.

Check the Catalog, etc., to ensure that product wiring is performed
correctly. Miswiring could result in damage to the EP Sensor and EP
Monitor, etc., or in abnormal operation.

Do not use the product in locations that are subject to direct sunlight
(ultraviolet rays), dust, salt, iron powder, high humidity, or in the
ambient atmospheres that include organic solvents, phosphate ester
type hydraulic oil, sulphur dioxide, chlorine gas, acids, etc. It could
lead to an early shutdown of some functions or a sudden degradation
of performance, and result in a reduced operating life.

The EP Sensor and EP Monitor use delicate electronic parts inside.
When handling, do not strike, drop, or bump the product so that it is
not subjected to excessive shocks. Even if it does not appear to be
damaged, internal parts could be damaged and erratic operation
could occur.

When installing the product, leave room for adequate working space
around it. Failure to ensure adequate working space will make it more
difficult to conduct daily inspections or maintenance, which could
eventually lead to system shutdown or damage to the product.

Always post an “operations in progress” sign for installations,
adjustments, or other operations, to avoid unintentional supplying of
electrical power, etc. Such accidental supplies may cause electric
shock or sudden activation of the product that could result in physical
injury.

Always read these precautions carefully before use.

DANGER

Expresses situations that can be clearly predicted as dangerous. 
If the noted danger is not avoided, it could result in death or serious injury.  
It could also result in damage or destruction of assets.

WARNING

Expresses situations that, while not immediately dangerous, could become dangerous. 
If the noted danger is not avoided, it could result in death or serious injury.  
It could also result in damage or destruction of assets.

CAUTION

Expresses situations that, while not immediately dangerous, could become dangerous.  
If the noted danger is not avoided, it could result in light or semi-serious injury. 
It could also result in damage or destruction of assets.

ATTENTION

While there is little chance of injury, this content refers to points that should be observed for
appropriate use of the product.

The directions are ranked according to degree of potential danger or damage: 
“DANGER!”, “WARNING!”, “CAUTION!”, and “ATTENTION!”

DANGER

WARNING

CAUTION

Содержание DTY-EPS Series

Страница 1: ...imum sensor for electrostatic monitoring of automated lines arrives Optimum sensor for electrostatic monitoring of automated lines arrives EP Sensor Environmentally friendly RoHS Compliant Product Environmentally friendly RoHS Compliant Product ...

Страница 2: ...utput and abnormality output to the EP Sensor unit Moreover since it can be connected directly to an external controller unit without passing through an amplifier etc the unit achieves a total space reduction Enables confirmation of ionizer performance with ion balance measurement function Easy checking of simple ion balance by mounting a monitor platenote Note Monitor plate is optional Component ...

Страница 3: ...d the software from the Koganei website Major characteristics Can perform displays of EP Sensor settings and measurement data Compatible OS Windows NT 2000 XP Windows is a registered trademark of Microsoft Corporation Features Safety Precautions Handling Instructions and Precautions EP Sensor Specifications EP Sensor Output Circuit and Cable Signal Table EP Monitor Specifications Internal Circuit ...

Страница 4: ...232C Terminal PC support software for settings use only for settings EP Sensor EP Monitor SW1 4 1ch 2ch 3ch 4ch External control device PLC PC etc Analog signal A S OUT S W OUT ch 1 2 3 4 PSU Cable DTY EPP CB L or equivalent Multiple RS232C ports are mounted on the monitor device to enable connection of multiple EP Sensors for centralized monitoring Setting is performed from the monitor device EP ...

Страница 5: ... may result in current leaks or defective continuity that could lead to fire electric shock or abnormal operation Do not throw the product into fire The product could explode and or release toxic gases Do not sit on the product place your foot on it or place other objects on it Accidents such as falling could result in injury Dropping or toppling the product may result in injury or it might also d...

Страница 6: ...ween the ion balance monitor mode and actual measured data output mode the reference electric potential is automatically set to the ground electric potential connected to the body Zero calibration Major parts and functions of EP Monitor Name Description q Alarm LED red Blinks when judgment output is ON lights up when sensor abnormality occurs w Power LED green Lights up when power supply is ON e C...

Страница 7: ...connector and pull it out At this time be careful to avoid applying unnecessary force on the lead wires Connector for 4 EP Sensors Connector for power supply switch and communication cable 1ch DTY EPP DTY EPS 2ch 3ch 4ch Power supply switch and communication cable EP Sensor Lock lever Lock lever 4 3 2 1 Attaching and removing of the EP Sensor and the power supply switch and communication cable Att...

Страница 8: ...tput Communication I F Sampling period Data output cycle Input output response time for averaged data output mode Note 1 Temperature characteristics Operating temperature range Operating humidity range Storage temperature range Cable length Case material Outer dimensions Mass Accessories Method Applied voltage Sink current Method Applied voltage Sink current Output voltage Zero point DTY EPS DTY E...

Страница 9: ...e will drop due to resistance in the cable Key to codes D Reverse current protection diode for power supply ZD1 ZD4 Zener diode for surge voltage absorption Tr1 Tr4 NPN output transistor Model Item Voltage Current Sensor input Switch output Electric potential display Switch output check display Input channel check display Setting key switch Communication I F Operating temperature range Operating h...

Страница 10: ...on cable CB No communication cable CC With communication cable Cable length 13L 3m 9 84ft 10L 10m 32 8ft Additional parts to be ordered separately Communication cable for EP Sensor 3m Monitor plate Component bracket DTY EPP BR2 DTY EPP MP DTY EPP CA 3L DTY EPU Protective front coverNote Blank Without protective front cover C With protective front cover Power supply switch and communication cable B...

Страница 11: ... 23 50 40 5 0 1 Ground washer 24V50mA 4 1 Ground washer Ground terminal 0 0 2 2 φ3 2 12 6 15 0 8 0 15 22 19 6 34 2 DTY EPS SER SER ALM POW CAL CAL POW ALM 24 32 With 2 pcs M4 0 7 length 10 hex socket head screws 2 φ4 2 2 M3 0 5 EP Sensor DTY EPS Can be moved to any desired angle Can be moved to any desired angle Detecting position 7 5 22 13 3 9 Detecting position 60 135 95 150 φ6 φ9 71 22 6 18 11 ...

Страница 12: ... 1 5V 1 V 4 T U O 3 T U O 2 T U O 1 11 10 1 2 V 0 3 T U O 4 5 6 7 8 D X R 9 D X T S T R S T C SENSOR V 0 V DC 24 1 c h 2 c h 3 c h 4 c h Wiring label enlarged view Connector for power supply switch and communication cable 12 4 15 6 14 9 5 9 5 Pin 1 4 3 2 1 2 φ4 5 9 11 4 5 16 11 2 φ2 9 9 6 7 24 7 30 4 38 12 6 1 6 With 2 hex socket head screws M2 6 0 45 length 5 29 8 9 5 50 L φ3 8 6 leads Power supp...

Страница 13: ...achining dimensions for the EP Monitor mounting hole 48 4 32 7 48 55 4 A S OUT S W OUT ch 1 2 3 4 DTY EPU 51 2 51 2 9 5 8 70 70 45 0 6 0 45 0 6 0 Notes 1 Use a mounting panel thickness of 1 to 3 2mm 2 If mounting in adjacent positions make the interval larger than the value shown in the figure above 3 Conforms to DIN43700 ...

Страница 14: ... 3 MEMO ...

Страница 15: ...ing from the defects KOGANEI CORP shall in no way be liable or responsible for injuries or damage to persons or property arising out of the use or operation of the manufacturer s product This warranty shall be void if the engineered safety devices are removed made inoperative or not periodically checked for proper functioning Any operation beyond the rated capacity any improper use or application ...

Страница 16: ...nei co jp OVERSEAS DEPARTMENT 3 11 28 Midori cho Koganei City Tokyo 184 8533 Japan Tel 042 383 7271 Fax 042 383 7276 MICHIGAN REPRESENTATIVE OFFICE 5070 East N Ave Kalamazoo Michigan 49048 U S A Tel 269 388 8769 Fax 269 388 8771 SHANGHAI KOGANEI INTERNATIONAL TRADING CORPORATION Room 2606 2607 Tongda Venture Building No 1 Lane 600 Tianshan Road Shanghai 200051 China Tel 021 6145 7313 Fax 021 6145 ...

Отзывы: