background image

Before use, be sure to read the “Safety Precautions” on p.

K

.

w

Application Examples

One EP Monitor can be connected up to 4 EP
Sensors, and used for switching displays

LED indicators and alarm signals available
when threshold is exceeded

If the setting voltage is exceeded, you can confirm it by the SW.OUT LED and
switch output (judgment output).

Communication function can be used
to make various parameter settings
(measurement distance, upper and
lower limit, operation mode, and data
output cycle)

ON

OFF

The upper and lower limit (threshold MAX, MIN) can be 
changed depending on the setting.

V

oltage

Upper limit:

MAX

(Threshold)

Lower limit:

MIN

(Threshold)

Judgment output

EP Monitor

CONTENTS

Support software (free)

Download the software from the Koganei website.

Major characteristics

• Can perform displays of EP Sensor settings and

measurement data.

(Compatible OS: Windows NT, 2000, XP)
*Windows is a registered trademark of Microsoft

Corporation.

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Safety Precautions . . . . . . . . . . . . . . . . . . . . 

Handling Instructions and Precautions . . . . . 

EP Sensor Specifications . . . . . . . . . . . . . . . 

EP Sensor Output Circuit and . . . . . . . . . . . . 
Cable Signal Table

EP Monitor Specifications . . . . . . . . . . . . . . . 

Internal Circuit and Wiring Specifications . . . 

Order Codes . . . . . . . . . . . . . . . . . . . . . . . . . 

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 

K

K

K

K

K

K

K

K

K

q

r

t

u

u

i

i

o

!0

Electric potential measurement
of wafers, etc.

Electric potential measurement
of glass substrates, etc.

Electric potential
measurement of
wrapping films, etc.

Electric potential
measurement of
plastic containers
and parts, etc.

Use the support software for
setting, display, and control.

Up to 4 EP Sensors can 
be connected.

EP Monitor

A. S. OUT

SW.OUT

ch

1

2

3

4

DTY-EPU

Caution

Before use, be sure to read the “Safety Precautions” on p.

r

.

Содержание DTY-EPS Series

Страница 1: ...imum sensor for electrostatic monitoring of automated lines arrives Optimum sensor for electrostatic monitoring of automated lines arrives EP Sensor Environmentally friendly RoHS Compliant Product Environmentally friendly RoHS Compliant Product ...

Страница 2: ...utput and abnormality output to the EP Sensor unit Moreover since it can be connected directly to an external controller unit without passing through an amplifier etc the unit achieves a total space reduction Enables confirmation of ionizer performance with ion balance measurement function Easy checking of simple ion balance by mounting a monitor platenote Note Monitor plate is optional Component ...

Страница 3: ...d the software from the Koganei website Major characteristics Can perform displays of EP Sensor settings and measurement data Compatible OS Windows NT 2000 XP Windows is a registered trademark of Microsoft Corporation Features Safety Precautions Handling Instructions and Precautions EP Sensor Specifications EP Sensor Output Circuit and Cable Signal Table EP Monitor Specifications Internal Circuit ...

Страница 4: ...232C Terminal PC support software for settings use only for settings EP Sensor EP Monitor SW1 4 1ch 2ch 3ch 4ch External control device PLC PC etc Analog signal A S OUT S W OUT ch 1 2 3 4 PSU Cable DTY EPP CB L or equivalent Multiple RS232C ports are mounted on the monitor device to enable connection of multiple EP Sensors for centralized monitoring Setting is performed from the monitor device EP ...

Страница 5: ... may result in current leaks or defective continuity that could lead to fire electric shock or abnormal operation Do not throw the product into fire The product could explode and or release toxic gases Do not sit on the product place your foot on it or place other objects on it Accidents such as falling could result in injury Dropping or toppling the product may result in injury or it might also d...

Страница 6: ...ween the ion balance monitor mode and actual measured data output mode the reference electric potential is automatically set to the ground electric potential connected to the body Zero calibration Major parts and functions of EP Monitor Name Description q Alarm LED red Blinks when judgment output is ON lights up when sensor abnormality occurs w Power LED green Lights up when power supply is ON e C...

Страница 7: ...connector and pull it out At this time be careful to avoid applying unnecessary force on the lead wires Connector for 4 EP Sensors Connector for power supply switch and communication cable 1ch DTY EPP DTY EPS 2ch 3ch 4ch Power supply switch and communication cable EP Sensor Lock lever Lock lever 4 3 2 1 Attaching and removing of the EP Sensor and the power supply switch and communication cable Att...

Страница 8: ...tput Communication I F Sampling period Data output cycle Input output response time for averaged data output mode Note 1 Temperature characteristics Operating temperature range Operating humidity range Storage temperature range Cable length Case material Outer dimensions Mass Accessories Method Applied voltage Sink current Method Applied voltage Sink current Output voltage Zero point DTY EPS DTY E...

Страница 9: ...e will drop due to resistance in the cable Key to codes D Reverse current protection diode for power supply ZD1 ZD4 Zener diode for surge voltage absorption Tr1 Tr4 NPN output transistor Model Item Voltage Current Sensor input Switch output Electric potential display Switch output check display Input channel check display Setting key switch Communication I F Operating temperature range Operating h...

Страница 10: ...on cable CB No communication cable CC With communication cable Cable length 13L 3m 9 84ft 10L 10m 32 8ft Additional parts to be ordered separately Communication cable for EP Sensor 3m Monitor plate Component bracket DTY EPP BR2 DTY EPP MP DTY EPP CA 3L DTY EPU Protective front coverNote Blank Without protective front cover C With protective front cover Power supply switch and communication cable B...

Страница 11: ... 23 50 40 5 0 1 Ground washer 24V50mA 4 1 Ground washer Ground terminal 0 0 2 2 φ3 2 12 6 15 0 8 0 15 22 19 6 34 2 DTY EPS SER SER ALM POW CAL CAL POW ALM 24 32 With 2 pcs M4 0 7 length 10 hex socket head screws 2 φ4 2 2 M3 0 5 EP Sensor DTY EPS Can be moved to any desired angle Can be moved to any desired angle Detecting position 7 5 22 13 3 9 Detecting position 60 135 95 150 φ6 φ9 71 22 6 18 11 ...

Страница 12: ... 1 5V 1 V 4 T U O 3 T U O 2 T U O 1 11 10 1 2 V 0 3 T U O 4 5 6 7 8 D X R 9 D X T S T R S T C SENSOR V 0 V DC 24 1 c h 2 c h 3 c h 4 c h Wiring label enlarged view Connector for power supply switch and communication cable 12 4 15 6 14 9 5 9 5 Pin 1 4 3 2 1 2 φ4 5 9 11 4 5 16 11 2 φ2 9 9 6 7 24 7 30 4 38 12 6 1 6 With 2 hex socket head screws M2 6 0 45 length 5 29 8 9 5 50 L φ3 8 6 leads Power supp...

Страница 13: ...achining dimensions for the EP Monitor mounting hole 48 4 32 7 48 55 4 A S OUT S W OUT ch 1 2 3 4 DTY EPU 51 2 51 2 9 5 8 70 70 45 0 6 0 45 0 6 0 Notes 1 Use a mounting panel thickness of 1 to 3 2mm 2 If mounting in adjacent positions make the interval larger than the value shown in the figure above 3 Conforms to DIN43700 ...

Страница 14: ... 3 MEMO ...

Страница 15: ...ing from the defects KOGANEI CORP shall in no way be liable or responsible for injuries or damage to persons or property arising out of the use or operation of the manufacturer s product This warranty shall be void if the engineered safety devices are removed made inoperative or not periodically checked for proper functioning Any operation beyond the rated capacity any improper use or application ...

Страница 16: ...nei co jp OVERSEAS DEPARTMENT 3 11 28 Midori cho Koganei City Tokyo 184 8533 Japan Tel 042 383 7271 Fax 042 383 7276 MICHIGAN REPRESENTATIVE OFFICE 5070 East N Ave Kalamazoo Michigan 49048 U S A Tel 269 388 8769 Fax 269 388 8771 SHANGHAI KOGANEI INTERNATIONAL TRADING CORPORATION Room 2606 2607 Tongda Venture Building No 1 Lane 600 Tianshan Road Shanghai 200051 China Tel 021 6145 7313 Fax 021 6145 ...

Отзывы: