Koehler K39400 Скачать руководство пользователя страница 9

K394XX Water Separability Tester 

Operation and Instruction Manual 

 
 

K394XX-Manual

    

 

-

5-

 

 

Drive: 

1/10 hp (75w) High 
Torque 

Run Time: 

1-50 Minutes 

Temperature 

Range: 

 
Ambient to 84°C 

Temperature 

Control Stability: 

 
± 0.05°C 

Capacity: 

Seven (7) 100mL 
graduated cylinders 

Construction: 

Stainless Steel Tank 
12 x 9.8 x 10.7 in. 

Bath Medium: 

Distilled 

Water or 

Suitable  Heat Transfer 
Fluid 

Bath Medium 

Capacity: 

 
4.5 gal (17L) 

 

 

2  Safety Information and Warnings 

 

Safety Considerations: 

The use of this 

equipment may involve 

hazardous 

materials and 

operations. This manual does not purport to 
address all of the safety problems associated 
with the use of this equipment. It is the 
responsibility of any user of this equipment to 
investigate, research, and establish appropriate 
safety and health practices and determine the 
applicability of regulatory limitations prior to use. 

 
Equipment Modifications and Replacement 
Parts: 

Any modification or alteration of this 

equipment from that of factory specifications is 
not recommended because it voids the 
manufacturer warranty, product safety, 
performance specifications, and/or certifications 
whether specified or implied, and may result in 
personal injury and/or property loss. 
Replacement parts must be O.E.M. exact 
replacement equipment. 
 

Unit Design: 

This equipment is specifically 

designed for use in accordance with the 
applicable standard test methods listed in 
section 1.2 of this manual. The use of this 
equipment in accordance with any other test 
procedures, or for any other purpose, is not 
recommended and may be extremely 
hazardous. 
 

Over temperature Protection:

  This unit is 

equipped with over  temperature Protection 

(OTP) circuitry to prevent overheating. The unit 
will automatically interrupt power whether 
equipment malfunction or operator error causes 
the temperature to exceed either 20 °C above 
the set point or the maximum recommended 
temperature range. The power can only then be 
restored by identifying and correcting the 
problem, allowing the unit to return to normal 
operating temperatures, and resetting the power 
to the unit. 
 

Chemical Reagents Information: 

Chemicals 

and reagents used in performing the test may 
exhibit potential hazards. Any user must be 
familiarized with the possible dangers before 
use. We also recommend consulting the 
Material Data and Safety Sheet (MSDS) on each 
chemical reagent for additional information. 
MSDS information  can be easily located on the 
internet at http://siri.uvm.edu or 

http://www.sigma-aldrich.com

. 

 

3  Getting Started 

 

The instructions for preparing the equipment 

assume that the user is aware of the contents of 
this document, which lists the warranty 
conditions and important precautions.

 

 

3.1 

Packing List 

 

 

K394XX Water Separability Tester  

 

332-002-018 100mL Graduated Cylinder, (7)  

 

K394XX-Manual K394XX Water Separability 
Instrument Operation and Instruction Manual 
 

Accessories (purchased separately): 

 

 

250-000-19F ASTM 19F Thermometer 

 

250-000-19C ASTM 19C Thermometer  

 

250-000-21F ASTM 21F Thermometer  

 

250-000-21C ASTM 21C Thermometer 

 

K39400-SFW 

Water Separability 

Data 

Acquisition Software  

 

3.2 

Unpacking 

 

1. 

Check Shock Watch Label on Cardboard 
Box for indication of rough handling and 
possible damage.  

 

2. 

Check labeling for correct orientation of 
instrument. (e.g. This Side Up) 

 

3. 

Carefully open top of box with box cutter and 
remove packing foam.  

 

Содержание K39400

Страница 1: ...venue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis...

Страница 2: ......

Страница 3: ...andards set forth in this certification Specifications ASTM D1401 ASTM D6074 ASTM D6158 ISO 6614 DIN 51599 FTM 791 3201 NF T 60 125 This unit is tested before it leaves the factory to ensure total fun...

Страница 4: ......

Страница 5: ...tement is given cataloging the items that require separation from the equipment along with basic information on subsequent processing or recycling prior to disposal of the equipment http www dpa syste...

Страница 6: ...minimum the following substances preparations and components have to be removed from any separately collected WEEE Mercury containing components such as switches or backlighting lamps compact fluores...

Страница 7: ...packing 5 3 3 Setup 6 4 Descriptions 7 4 1 Description of Instrument Controls 7 4 2 Temperature Controller Operation 7 5 Operation 9 5 1 Bath 9 5 2 Power 9 5 4 Test Control Panel Operation 11 6 Safety...

Страница 8: ...ducts are backed by our staff of technically knowledgeable trained specialists who are experienced in both petroleum products testing and instrument service to better understand your requirements and...

Страница 9: ...Over temperature Protection This unit is equipped with over temperature Protection OTP circuitry to prevent overheating The unit will automatically interrupt power whether equipment malfunction or op...

Страница 10: ...red glass front panel jar pose a hazard to personnel Impacts to these during normal operation can shatter the glass components releasing the bath fluid posing thermal burn hazards and slipping hazards...

Страница 11: ...g Bath Stainless Steel Bath with clear tempered glass front viewing window for stabilizing the bath temperature to desired setting within 0 05 C 6 Cylinder Ports The test cylinder is placed into the h...

Страница 12: ...ture Calculate the difference between the measuring device and the Process value displayed on the controller b Press the program key two times until PCt is displayed in the lower green LED display Pre...

Страница 13: ...ium must be changed See Draining instructions in section 7 3 of this document When a decision is made to discard this material dispose of this material and its container to a hazardous of special wast...

Страница 14: ...e rail Otherwise shaft may get bent or damaged and will no longer be useful for operation 6 Lift the Stirrer shaft up then move the head assembly left or right until stirrer paddle is over the sample...

Страница 15: ...op button may be used to interrupt the 10 second audible alarm 11 At the end of the stirring period please follow the appropriate test method such as those listed in section 1 2 for determining the wa...

Страница 16: ...atus is equipped with Over temperature Protection OTP circuitry which prevents the unit from exceeding unsafe operating temperatures If the unit cannot maintain the set point temperature and begins to...

Страница 17: ...ior with organic chemicals such as Acetone Toluene Hexane etc For more difficult cleaning of finished surfaces a dilute solution or isopropanol in water may be used It is not recommended that more agg...

Страница 18: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 14 8 Wiring Diagrams 8 1 K39400 Unit Wiring...

Страница 19: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 15...

Страница 20: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 16...

Страница 21: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 17 8 2 K39496 Unit Wiring...

Страница 22: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 18...

Страница 23: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 19...

Страница 24: ...eturn of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or...

Страница 25: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 21 Notes...

Страница 26: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 22 Notes...

Отзывы: