Chapter 2 Method of installation
MDC-2900 Series
2-10
0092629012-07
2.3.3 Installation of MRO-105
2.3.3.1 Installation of Operation unit MRO-105
(1) Remove the corner guard caps of four places on the Operation unit. Insert the tip of a small
flat-blade screwdriver carefully between a corner guard cap and the front bezel of Operation
unit to make a gap, and then pinch and pull up the corner guard cap with fingers. Take care
not to damage the bezel of Operation unit by the tip of flat-blade screwdriver.
(2) Remove M4 (4 mm) screws and remove the Operation unit from the mounting bracket.
(3) Mark the place as shown in the following figure, and then secure the mounting bracket with
5M (5 mm) tapping screws at four places.
(4) Secure the Operation unit to clamps with M4 (4 mm) screws that were removed in (2) and fit
the corner guard caps of the four corners.
Figure 2.11 Installation of MRO-105
Corner guard cap (4 places)
Operation unit
M4 screw
(4 places)
M5 screw
(4 places)
Clamp (left)
Clamp (right)
Unit: mm (inch)