Chapter 2 Method of installation
MDC-2900 Series
2-8
0092629012-07
2.3.1.2 Flush Mounting of MRD-105
Preparation:
Installation:
(1) Place the Display unit in the precut opening on the panel.
(2) Secure the Display unit with 8 places fastened with M4 screw as shown in the following figure.
Figure 2.8 Opening and nut-holes for display unit
(1) Cut an opening and drill 4.5
mm eight holes with the size
shown in Figure 2.8, on the side
for attachment of a display unit
on a panel.
(2) Unscrew four knob bolts that
hold the display unit to the
mounting bracket.
(3) Remove the display unit from
the mounting bracket and put it
on a horizontal stable place.
Figure 2.9 Flush-mount Installation
4mm screw for 8holes
M4 screw
(8 places)
Display unit
Unit: mm (inch)
8-
φ
4.5
(11/64)