Chapter 2 Operation and Setting
KSD-1100/1210
0093107081-00
2-26
vector (1 minute position vector, 3 minutes position vector, 6 minutes position vector, 12 minutes
position vector). The position vector line can be calculated according to the current speed x time.
[4] Position tracking: Provide on / off selection for setting. If set to on, the ship position can be displayed
on the screen according to the setting item of [Display Position].
[5] Refresh position: When [Position tracking] set to on, provide center of the screen / one third from the
edge screen for selection Settings, select screen center, refresh the position of the ship in the center of
the screen every 10 seconds, select one third from the edge screen, when the ship sails out of the
screen, automatically adjust the position of the ship in the forward direction of the ship one third from
the edge screen position.
2.3.2.7.4 AIS Target Display
Click "AIS target display" to enter the AIS target display setting page, with details as shown in the figure
below.
[1] Heading line (HDT): Choose to turn off the heading line display and set the display length (short,
medium, long) and time position vector line (1 minute position vector, 3 minutes position vector, 6
minutes position vector, 12 minutes position vector, 24 minutes position vector). The time position
vector line refers to the expected walking length within the set time.
[2] Course line (COG): Choose to turn off the bow line display and set the display length (short, medium,
long) and time position vector line (1 minute position vector, 3 minutes position vector, 6 minutes
position vector, 12 minutes position vector, 24 minutes position vector).
[3] CPA line: Turn on or off the display of the CPA line between the ship and the target ship.
[4] AIS Target Track Display: The targets for displaying trails can be set to all targets, Class A targets,
Class B targets, and Favorite AIS targets.
[5] AIS Target Track Length: AIS target track length can be turned on or off and the display duration can
be set. The display duration can be set to 3 minutes, 6 minutes, 12 minutes or 24 minutes.
[6] Lost time: If the AIS vessel does not update the information within the set not updated blanking time,
the vessel will be automatically blanked from the chart and the list. The duration can be set to 6 minutes
or 12 minutes.