- 30 -
INSTALLATION
WIRING JUNCTION BOX (DJB-540)
HULL UNIT (DHU-530)
Main Fuse
For Main Power Supply of Junction Box
Use the specified fuse as follows,
24V
→
4A.
Motor Fuse
For Hoist Motor
Use the specified fuse as follows,
24V
→
8A.
Power Supply Cable
connects the DC power supply
for activating the Hull unit.Use
the voltage in the range
21.6 to 31.2Volts.
Hoist Motor Cable
connects the Hoist Motor Cable from the
Hull unit.
I/Fcable
connects I/F cable to the Processor unit.
Earth Terminal
Transducer unit Cable
connects the Transducer unit
Cable from the Transducer unit.
Hoist Motor Cable
connects the Hoist Motor Cable
to the Junction Box.
Limit Switch Cable
connects the Limit Switch Cable
to the Junction Box.
Limit Switch Cable
connects the Limit Switch Cable
from the Huii unit.