Adjustments
SM7648-1 – 11NOV05
33
LENS - “EIS Confirmation and Adjustment”
Adjustment Specification
Prerequisites:
None
To Check:
You cannot check this adjustment.
To Adjust:
[1] Set the CAMERA 114 +/- 1 cm (44.9 +/- 0.4 in.) from the TARGET by using.
• SLOT 6
• red holes
• CAMERA NEST in the red hole for the TRIPOD
[2] Do
“Connecting to the SERVICE SOFTWARE” on Page 75
.
[3] In the “Cal Data” field, type: 2
Purpose:
To provide calibration information for the CP1 BOARD - MCU to adjust the position of the
LENS.
Do When:
After installing a new:
• CP1 BOARD - MCU
• MONITOR LCD AY
• LENS AY
Specification:
“FOCUS OK” displays.
Special Tools:
• SERVICE SOFTWARE
• Computer
• 5 V AC ADAPTER
• USB CABLE
• TARGET - shift lens adjustment