Diagnostics
SM7648-1 – 11NOV05
21
[22] De-energize the CAMERA.
[23] Check the de-energize sequence:
• MONITOR LCD displays black
• LENS moves in
• POWER LED de-energizes
[24] Remove the CAMERA from the CAMERA DOCK.
[25] Install a new BATTERY that has a full charge.
[26] Energize the CAMERA.
[27] Check the energize sequence. See
Step 21
.
[28] Press:
• “EVF/LCD” BUTTON to check that the view moves from the MONITOR LCD and the VIEWFINDER AY
• “EVF/LCD” BUTTON again to illuminate the MONITOR LCD
Important
The default position is “Wide”.
[29] Move the ZOOM LEVER to check that the LENS moves from “Wide” to “Tele” position.
[30] Check:
• ZOOM indicates on the MONITOR LCD
• MONITOR LCD is in focus when the LENS stops moving from “Wide” to “Tele” position
[31] Press the SHUTTER BUTTON to capture an image.
[32] Check that the MONITOR LCD displays:
• image
• number of additional images that can be captured
• icons:
– “Flash” mode
– quality of the image
– type of memory
[33] Press the “EVF/LCD” BUTTON to move the view to the VIEWFINDER AY.
[34] Check that the view is in focus.
[35] Move the ZOOM LEVER to check that the LENS moves from “Tele” to “Wide” position.
[36] Check:
• ZOOM indicates on the VIEWFINDER AY
• VIEWFINDER AY is in focus when the LENS stops moving from “Tele” to “Wide” position
[37] Press the SHUTTER BUTTON to capture an image.
[38] Check that the VIEWFINDER AY displays:
• image
• number of additional images that can be captured
• icons:
– “Flash” mode
– quality of the image
– type of memory
[39] Press the “EVF/LCD” BUTTON to move the view to the MONITOR LCD.