Supervisor Menu on Digital Panel
Untrained personnel should not alter any setting in the supervisor menu.
# PROGRAMS: 10
SECURITY: NO
COOLDOWN: 4.0
RUNNING PROG: 1
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
-
+
-
+
-
+
-
+
TEST: YES
NO
YES
PROGRAM
-
+
Press and hold down both arrow keys for at least
three seconds to enter the supervisor menu.
The following are parameters that
can only be set in the supervisor
menu.
COOLDOWN is the time that the machine waits
after sealing the bag/pouch before the seal bars retract.
This allows time for the actual seal to cool down and
take set. The range is 1 to 8 seconds.
Press the MENU key.
SECURITY can be turned on by selecting “YES.” If
security is on, the operator menu will be read only and
the operator will not be able to change any settings.
Press the MENU key.
This specifies the maximum number of programs that
may be saved in memory. Each program may have its
own set of unique parameters. The range is 1 to 10.
Press the MENU key.
If TEST is set to “YES” (using the UP arrow key), the
vacuum and vent valve may be operated manually. The
UP arrow key activates the vacuum valve, the DOWN
arrow key activates the vent valve, and pressing both
at the same time turns them both off. As you activate
either valve the vacuum pressure is displayed.
Press the MENU key.
This is the Main Menu screen. When the machine
starts up, the last program that was run will be the
current program shown in the window.
Figure 4.4