![Koch Ultravac 250 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/koch/ultravac-250/ultravac-250_owners-manual_1982708012.webp)
8 6 0 1 0 8 • Q
MAIN: 816-753-2150
TOLL FREE: 800-777-5624
INTERNET: kochequipment.com
E-MAIL: [email protected]
O P E R A T I O N • P A G E 3 . 4
VACPLUS: 4.0
SEAL: 1.2
VACUUM: 98
RUNNING PROG: 1
NO
-
+
PROGRAM
YES
-
NO
YES
PROGRAM
+
NO
-
YES
+
PROGRAM
YES
PROGRAM
+
-
NO
Operator Menu on Digital Panel
NOTE:
if the supervisor has set security on, these settings cannot be changed.
This is the Main Menu screen. When the
machine starts up, the last program that was
run will be the current program shown in
the window. To set the operating parameters
for the program shown press the MENU key.
VACUUM is set to % vacuum using the UP
and DOWN Arrow Keys.
The range is 30% to 99%.
Press the MENU key.
VACPLUS may be set from 0 to 20 seconds.
A setting greater than 0 allows the pump
to continue evacuating the chamber (for
the specified number of seconds) after the
pressure in the chamber has reached the %
vacuum set in the vacuum menu.
Press the MENU key.
The SEAL setting is in seconds. Use the UP
and DOWN arrow keys to change the seal
time. The range is 0 to 2 seconds.
Press the MENU key.
Figure 3.4