8
Technical data
42
Dielectric constant
≥ 5 for mono-rod probe/cable probe
*
≥ 1.8 with coaxial tube
Conductivity
No limitation
Maximum change of level
4)
500 mm/s
Inactive area at process connection
2)
25 mm
Inactive area at end of probe
1)
10 mm
1)
With water under reference conditions.
2)
With parameterized container with water under reference conditions, otherwise 40 mm.
3)
Depends on measuring mode (high-speed < 400 ms, high accuracy < 2,800 ms)
4)
Depends on configuration (MaxCol - maximum change of level)
8.3
Reference conditions
Container with diameter
1 m
Minimum distance to built-in components
> 300 mm
Distance from end of probe to tank bottom
> 15 mm
Air humidity
65% ± 20%
Temperature
+20°C ± 5°C
Pressure
1,013 mbar abs. ± 20 mbar
Medium
Water, DK = 80
Centered installation of sensor
l
Container parameterization carried out
l
* in preparation