13. Ordering details 

KAL-Ex

 

measuring system 

always consists of a sensor and an electronic analyzer. 

 

Senor order details

 (example: 

KAL-1308 Ex

  

Connection 

Order numbers 

Electrical connection/ 

version 

Sensor with insertion fitting 

Sensor with inline fitting 

1.4301 

1.4571 

Fitting brass / 

Sensor 1.4301 

Fitting 1.4301/ 

Sensor 1.4301 

1

/

KAL-1308 KAL-1408 KAL-1108 KAL-1208 

00=2 m PVC cable 

 

HT=2 m Silicone cable 

 

YP=PVC cable/ 

special length 

 

YS=Silicone cable/ 

special length 

 

YY=Special cable/ 

special length 

 

Ex=Ex-Sensor, 

PVC cable 

ATEX/IECEx 

(specify cable length)

 

3

/

- - 

KAL-1110 

KAL-1210 

1

/

KAL-1315 KAL-1415 KAL-1115 KAL-1215 

3

/

KAL-1320 KAL-1420 KAL-1120 KAL-1220 

G 1 

- - 

KAL-1125 

KAL-1225 

G 1

1

/

- - 

KAL-1132 

KAL-1232 

G 1

1

/

- - 

KAL-1140 

KAL-1240 

M 12 x 1 

KAL-0312 

- - - 

1

/

NPT 

KAL-5308 KAL-5408 KAL-5108 KAL-5208 

3

/

NPT 

- - 

KAL-5110 

KAL-5210 

1

/

NPT 

KAL-5315 KAL-5415 KAL-5115 KAL-5215 

3

/

NPT 

KAL-5320 KAL-5420 KAL-5120 KAL-5220 

 
 

Electronics order details 

(example:

 KAL-E30Ex

 

Field of 

application 

Flow trend 

indication 

Temperature 

monitoring 

Supply voltage 

24 V

DC

 24 

V

AC

 110 

V

AC

 230 

V

AC

 

Flow -  - 

KAL-E13 KAL-E12 KAL-E11 KAL-E10 

KAL-EH13 KAL-EH12 KAL-EH11 KAL-EH10 

Flow 8-LEDs  - 

KAL-E23 KAL-E22 KAL-E21 KAL-E20 

KAL-EH23 KAL-EH22 KAL-EH21 KAL-EH20 

Flow/ 

Temperaturw 

8-LEDs 

-20...+80°C  KAL-E33 KAL-E32 KAL-E31 KAL-E30 

0...+120°C  KAL-EH33 KAL-EH32 KAL-EH31 KAL-EH30 

Flow/ 

Temperature 

8-LEDs -20...+80°C 

– KAL-E32Ex 

– KAL-E30Ex 

 

Содержание KAL-0312 EX

Страница 1: ...Operating Instructions for Flow sensor model KAL Ex with Electronic Analyzer Model KAL E Ex...

Страница 2: ...nt 8 8 3 Expanding the trend indicator 8 8 4 Resetting the adjustment 9 8 5 Switching point setting 9 8 6 Temperature compensation 10 9 Fault alarms 10 10 Maintenance 10 11 Brief operating instruction...

Страница 3: ...devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accident...

Страница 4: ...by a series of constantly illuminated LEDs on the LED strip display The currently set switching point is indicated on the LED strip display by the individually blinking LED Sensors These sensors are...

Страница 5: ...he manufacturer s specifications may invalidate its warranty Therefore any resulting damage is not the responsibility of the manufacturer The user assumes all risk for such usage 5 Operating Principle...

Страница 6: ...tend at least 5 mm better 5 mm into the pipe see below 6 3 Mounting position The sensors can be mounted in any position provided that the piping is completely filled with the liquid to be monitored Th...

Страница 7: ...ice Connect the sensor cable to terminals 6 and 8 of the electronic analyzer Connect the supply line power supply to terminals 15 and 16 Caution The relays are shown in the rest positions The intrinsi...

Страница 8: ...point pen The flow LED 6 will blink for approximately 30 seconds After this time has expired the flow LED 6 will stop blinking If the system is not functioning properly the flow LED 6 will blink cont...

Страница 9: ...ic liquid being measured see above you can then set the switching point Adjust the flow rate Rotate the flow potentiometer 1 counterclockwise as far as it will go to the left hand stop The first LED i...

Страница 10: ...to blink After 10 seconds they will go out If the system is not functioning properly the flow LED 6 will blink continuously In this case press the SET button 5 once again The device then switches bac...

Страница 11: ...g range Turn to the right hand stop 2 Potentiometer for setting the temperature switching point SET button 5 for adjustment expanding measuring range 6 Flow LED illuminates when flow is greater than t...

Страница 12: ...ints compensation at potentiometer Switching function relay is operated with flow terminal 9 10 closed LED illuminated relay is operated when temperature is exceeded LED illuminated terminal 12 13 clo...

Страница 13: ...1210 G 1 2 KAL 1315 KAL 1415 KAL 1115 KAL 1215 G 3 4 KAL 1320 KAL 1420 KAL 1120 KAL 1220 G 1 KAL 1125 KAL 1225 G 11 4 KAL 1132 KAL 1232 G 11 2 KAL 1140 KAL 1240 M 12 x 1 KAL 0312 1 4 NPT KAL 5308 KAL...

Страница 14: ...s flats A B C D A B C D E M 12x1 SW 19 23 43 G 1 4 SW 27 10 50 81 G 1 4 SW 19 26 43 G 1 2 SW 27 10 50 81 G 1 2 SW 27 43 58 G 3 4 SW 32 15 52 82 5 G 3 4 SW 32 43 58 G 1 SW 39 15 56 85 1 4 NPT SW 19 26...

Страница 15: ...s Part 0 General Requirements EN 60079 11 2012 Explosive atmospheres Part 11 Equipment protection by intrinsic safety i Ebenfalls mit folgenden Europ ischen und nationalen Normen und technischen Vorsc...

Страница 16: ...8 done at Hofheim on April 11th 2018 Name des Unterzeichners Name of signatory Name des Unterzeichners Name of signatory H Peters Gesch ftsf hrer CEO Manfred Wenzel Prokurist authorized signatory Unte...

Страница 17: ...KAL EX KAL EX K05 0322 page 17 16 EC type examination certificate...

Страница 18: ...KAL EX page 18 KAL EX K05 0322...

Страница 19: ...KAL EX KAL EX K05 0322 page 19 17 IECEx certificate...

Страница 20: ...KAL EX page 20 KAL EX K05 0322...

Страница 21: ...KAL EX KAL EX K05 0322 page 21...

Страница 22: ...KAL EX page 22 KAL EX K05 0322...

Страница 23: ...KAL EX KAL EX K05 0322 page 23...

Отзывы: