![Kobold HND-P215 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/kobold/hnd-p215/hnd-p215_operating-instructions-manual_1982446008.webp)
HND-P215
page 8
HND-P215 K06/0422
- If a zero point adjustment was carried out the display shows ”Corr” after a restart .
7.6 Operation
Connect sensor, turn on device via
key.
After segment test
the device displays some configuration:
If the logger function is not off the time of the integrated clock will shortly be
displayed.
If a zero point adjustment was carried out the display shows shortly „nuLL Corr“.
After changing the battery the clock-setting menu is activated automatically
(‚CLOC‘). Check the clock and adjust, if necessary (p.r.t. chapter 7.7). After that the
device is ready for measuring.
7.7 Configuration
To change device settings, press
Menu
(key 4) for 2 seconds. This will activate the
configuration menu (main display: „SEt“).
Pressing key
Menu
changes between the menus, pressing
(key 3) jumps to the
referring parameters, which can be selected with key
(key 3).
The parameters can be changed with
(key 2) or
(key 5).
Pressing
Menu
again jumps back to the main configuration menu and saves the
settings.
Quit
(key 6) finishes the configuration and returns to standard measuring operation.
Menu
Parameter
Values
Meaning
KEY
Menu
KEY
KEY
or
SEt
ConF
Set Configuration: Generic Configurations
Unit
mbar,bar..
Unit: Unit of display (given by sensor 1 when using 2
sensors)
*,**
SL
oFF/on
Sea level correction: on or off (only for Sensor 1)
*,**
Alti
-2000..9999
Altitude above sea level [m] (only for Sensor1 and if SL )
*,**
rAtE
Rate: Measuring rate (p.r.t. chapter
7.7.1)
*
Slo
Slow measuring rate (4 Hz filtered, low power consumption)
*
FASt
Fast measuring rate, filtered (>1000Hz)
*
P.dEt
Peak detection: fast measuring rate, unfiltered (>1000Hz)
*
t.AVG
1-120
Averaging period in seconds, used by the averaging function
oFF
Averaging function deactivated
P.oFF
1-120
Auto Power Off time in minutes
oFF
Auto Power Off deactivated
Out
oFF
Function of the output: No output function, lowest power
consumption
Ser
Output is serial interface
dAC
Output is analogue output 0…1 V