12. Order codes
Example: DON-H10H R1 1 H0 M 0
Measuring
range
Housing
material
2)
Connection
O-ring
Material
Electronics
Cable entry
Option
[l/min]
Stainless
steel
0.5 – 36 l/h
DON-H05H
R1
= G ⅛
N1
= ⅛” NPT
1
= FKM
3
= FEP-
O-ring
4
= NBR
5
= Fluoroprene®
9
= Special
materials (not
for ATEX)
H0
= hall sensor (Push-Pull)/
reed switch, pulse output
HA
= H0 + ATEX (Exi)
Z1
= dual LCD totalizer
Z2
= Dosing unit LCD
Z3
= LCD totalizer/rate,
outputs:
4-20 mA, alarm, pulse
(ZOK-Z3) (impulses not
for battery supply
Z5
= as Z3, but with 2 relays/
SPDT relays
1A
4)
= E1 + HA (ATEX Exi)
2A
4)
= E2 + HA (ATEX Exi)
3A
4)
= E3 + HA (ATEX Exi)
5A
4)
= E5 + HA (ATEX Exi)
M
= M20
N
= ½“ NPT
S
3)
= M20 +
cooling
fin
T
3)
= ½“ NPT
+ cooling
fin
0
= without
N
= without battery
Y
= special
option,
(specify in
clear text; not
for ATEX)
2 – 100 l/h
DON-H10H
1)
R2
= G ¼
N2
= ¼“ NPT
15 – 550 l/h
DON-H15H
1)
R2
= G ¼
N2
= ¼“ NPT
1 – 40
DON-H20H
1)
R4
= G ½
N4
= ½“ NPT
1)
Replace Hxx with Sxx for special rotor for higher viscosities ˃ 1000 cP
2)
Replace ‘H’ with ‘G’ to order GPH (GPM) (e. g. 15 G instead of 15H)
3)
Only for electronic options -Zx
4)
E1/E2/E3/E5 = Z1/Z2/Z3/Z5 in ATEX version (Exi), without backlighting
Measuring
Range
Stainless Steel
Housing
2)
Connection
O-Ring Material
Electronics
Cable Entry
Option
0.13...9.5 GPH
DON-H05G..
..N1..
=
1
⁄
8
" NPT
..R1..
= G
1
⁄
8
..1..
=
FKM
..3..
= FEP-O-Ring
..4..
= NBR
..
5..
= Fluoroprene
®
..9..
= Special
Materials
(not for
ATEX)
..H0..
= Hall Sensor (Push-Pull) /
Reed Switch, Pulse Output
..HA..
= H0 + ATEX (Exi)
..Z1..
= Dual LCD Totalizer
..Z2..
= Batching Unit LCD
..Z3..
= LCD Totalizer, Rate, Outputs:
4-
4-20 mA, Alarm, Pul
(ZOK-Z3) (Impulses not for
Battery Supply)
..Z5..
= Z3 + 2 SPDT Relays
..1A
4)
..
= E1 + HA ATEX (Exi)
..2A
4)
..
= E2 + HA ATEX (Exi)
..3A
4)
..
= E3 + HA ATEX (Exi)
..5A
4)
..
= E5 + HA ATEX (Exi)
..M
= M20
..N
= ½" NPT
..S
3)
= M20 with
Cooling
Fin
..T
3)
= ½" NPT
with
Cooling
Fin
..0
= without
..N
= Without
Battery
..Y
= Special
Option
(Specify in
Clear Text,
not for ATEX)
0.5...27 GPH
DON-H10G..
..N2..
.= ¼" NPT
..R2..
= G ¼
4...145 GPH
DON-H15G
1)
..
..N2..
= ¼" NPT
..R2..
= G ¼
0.26...10.6 GPM
DON-H20G
1)
..
..N4..
= ½" NPT
..R4..
= G ½
Order Details (Example: DON-H10G N1 1 R0 M 0)
1)
Replace Hxx with Sxx for special rotors for viscosities > 1000 cP
2)
Replace 'G' with 'H' to order LPH (LPM) (e.g. 15 H instead of 15 G)
3)
Only for electronic options ..Zx
4)
E1/E2/E3/E5 = Z1/Z2/Z3/Z5 in ATEX version (Exi), without backlighting
Содержание DON-05
Страница 1: ...Operating Instructions for Oval Wheel Flowmeter High pressure Model DON H...
Страница 9: ...DON H DON H 01 0721 page 9 Note The electronic option H0 is available with reed switch output...
Страница 14: ...DON H page 14 DON H 01 0721 7 4 2 Wiring with ZOK ZxP a Circuit with Hall sensor b Circuit with Reed switch...
Страница 43: ...DON H DON H 01 0721 page 43 17 Statement of Conformity...
Страница 44: ...DON H page 44 DON H 01 0721...
Страница 45: ...DON H DON H 01 0721 page 45...
Страница 46: ...DON H page 46 DON H 01 0721...
Страница 47: ...DON H DON H 01 0721 page 47...
Страница 48: ...DON H page 48 DON H 01 0721 18 State of safeness...