![Kobold DON-05 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/kobold/don-05/don-05_operating-instructions-manual_1982403025.webp)
DON-H
DON-H
01/0721
page 25
Output Pulse Resolution -H0/HA
Model
Measuring
range
[L/min]
Pulse / litre
Reedswitch
Hall sensor
DON-H05
0,5 - 36 L/h
2670
2670
DON-H06
2-36 L/h
2670
2670
DON-H10
2 - 100 L/h
1054
1054
DON-H15
15 – 550 L/h
355
710
DON-H20
1-40
82
163
The values in above table are only approximate guidelines. The actual value for
pulse rate can deviate from the values in this table and is mentioned in
calibration certificate delivered with the flowmeter.