Содержание Portavo 904 COND

Страница 1: ...0 ATEX E089 X II 1G Ex ia IIC T3 T4 T6 SE 706X 2 NMSN 14163 Berlin BVS 10 ATEX E089 X II 1G Ex ia IIC T3 T4 T6 II 1G Ex ia IIC T3 T4 T6 SE 706X 1 NM 14163 Berlin BVS 10 ATEX E II 1G Ex ia IIC SE 706X 2 NM 14163 Berlin BVS 10 ATEX E II 1G Ex ia IIC x ia IIC T3 T4 T6 ATEX E 089 X SE 706X 2 NMS 14163 Berlin BVS 10 ATEX E0 II 1G Ex ia IIC T Latest Product Information www knick de Portavo 904 X COND Us...

Страница 2: ......

Страница 3: ... given If the device has been in contact with process fluids it must be decontaminated disinfected before shipment In that case please attach a corresponding certificate for the health and safety of our service personnel Registered trademarks The following names are registered trademarks For practical reasons they are shown without trademark symbol in this manual Calimatic Memosens Paraly Portavo ...

Страница 4: ...Sensor 15 Switching On the Meter 16 Icons 16 Configuring 17 Calibrating 18 Measuring 21 Toggling between Compensated and Uncompensated Measured Values 21 Data Logger 22 Operating Modes of the Data Logger Logger Type 23 Data Logger Menu 25 Configuring the Data Logger 26 Starting the Data Logger using CONT 27 Starting the Data Logger using START 27 Displaying the Logger Data 28 Stopping the Data Log...

Страница 5: ...5 Table of Contents Error Codes and Device Messages 32 Sensoface Messages 33 Error Messages 34 Product Line 35 Sensors 35 Conductivity Standards 36 Accessories 36 Specifications 37 Index 40 ...

Страница 6: ...the Portavo 904 X COND includes The Portavo 904 X COND incl 4 AA batteries and premounted quiver Carrying strap Quickstart instructions in various languages Specific test report Safety instructions Certificates Data carrier with detailed user manuals and Paraly SW 112 software USB cable 1 5 m ...

Страница 7: ...ety Instructions In official EU languages and others EC Declarations of Conformity Quickstart Guides Installation and first steps Operation Menu structure Calibration Error messages and recommended actions Various languages on CD ROM and on our website www knick de Specific Test Report Certificates IECEx ATEX Documentation ...

Страница 8: ...when exposed to extreme moisture Overview of the Portavo 904 X COND Quiver Scratch proof clear glass display perfectly readable even after years Very long operating times with one set of batteries 4 x AA or use of a Li ion battery for reliable operation even at high or very low operating temperatures Li ion battery not suited for Portavo 904 X COND for application in a hazardous location Data logg...

Страница 9: ...on the right Furthermore Memosens allows the storage of cal ibration data which will be available and can still be used when the sensor is connected to another Memosens capable device Sensoface Sensoface provides quick information on the sen sor condition The three smiley faces as shown on the right represent the sensor condition during measurement and after a calibration When the condition deteri...

Страница 10: ...r side of the cover explains the control functions and device messages Hook A fold out hook on the back allows suspending the meter This leaves your hands free for the actual measurement The rating plate is located beneath the hook Protective Cover and Hook Combined Cover and hook can be joined together to form a benchtop stand allowing com fortable and fatigue free working at a lab bench or desk ...

Страница 11: ...e time Additional information is provided by means of icons Sensoface battery icon etc Some typical displays are shown here Measuring display of measured value and temperature Calibration Calibration by entry of cell constant Logger data display of measured value memory location temperature date and time Clock display of hours and minutes seconds and date Calibration with KCl solution ...

Страница 12: ...ata see Start up meas Switches the meter on Activates measuring mode Stops the data logger cal Starts calibration set Activates configuration Confirms entries clock Displays time and date allows setting the clock using set RCL View stored values STO Holds and saves a measured value allows setting and starting the logger by pressing set page 22 When this icon is displayed you can use the arrow keys...

Страница 13: ...rform the intended function prolonged storage at temperatures above 70 C severe transport stresses In this case a professional routine test must be performed This test should be carried out by the manufacturer A special lithium ion battery suited to the battery compartment is available for the Portavo 904 The battery is recharged through the USB port Note Not available for the Portavo 904 X device...

Страница 14: ...ous Locations Batteries 4x each Temp class Ambient temperature range Duracell MN1500 T4 10 C Ta 40 C Energizer E91 T3 10 C Ta 50 C Power One 4106 T3 10 C Ta 50 C Panasonic Pro Power LR6 T3 10 C Ta 50 C A battery icon in the display indicates the battery power level Icon fully filled Batteries at full capacity Icon partially filled Battery capacity is sufficient Icon empty Battery capacity not suff...

Страница 15: ...ognizes a connected Memosens sensor and switches accordingly Memosens is signaled in the display Connections a Micro USB port b M8 4 pins for Memosens sensors c Temperature probe GND d Temperature probe e DIN socket 8 pins for analog sensors Start Up Memosens sensors have a cable coupling which allows convenient replacement of sensors while the cable remains connected to the meter The connecting c...

Страница 16: ...hed on with the meas key it immediately switches to measuring mode Depending on the connected sensor and the specific measuring task several steps for configuration and calibration must be per formed as described on the following pages Start Up Error message Battery charging level Sensor condition Memosens sensor Temperature detection sensor separate or manual Icons Important information about the...

Страница 17: ...TDS mg l C MOHM cm OFF On Cond Unit mS cm S m TDS Factor 0 0 1 0 if display TDS TC OFF LINEAR NLF NACL HCL NH3 NAOH if display Cond TC LINEAR 0 0 20 0 K 2 0 K if TC LINEAR REF Temp 0 100 C 25 C 32 212 F 77 F if TC LINEAR CAL CELL CONST COND 0 01 MOL KCL 0 1 MOL KCL FREE CAL Auto OFF OFF 0 1h 1h 6h 12h Temp Unit C F Time Format 24h 12h Date Format dd mm yy mm dd yy Default NO YES reset to factory s...

Страница 18: ...The calibration method is selected in the configuration menu Measurement CAL COND Dip sensor in solution Value blinks Use st to adjust the temperature corrected conductivity value Caution Here the meter does not perform a temperature compensation Calibration is performed Automatic return to measuring mode COND Calibration Calibration by entry of cell conductivity The calibration method is selected...

Страница 19: ...erature Conductivity KCl Hourglass blinks Calibration is performed Automatic return to measuring mode Caution Make sure that the values of the calibration solutions used corre spond exactly to those specified in this manual If not the resulting cell constant will be incorrect Caution When calibrating in a liquid make sure that the sensor the separate temperature probe if present and the calibratio...

Страница 20: ...od FREE CAL calibration is selected in the configuration menu Measurement CAL CELL CONST blinks Use st to select the desired calibration method CELL CONST COND 0 01 MOL KCL or 0 1 MOL KCL Perform the selected calibration see CELL CONST COND or 0 01 0 1 MOL KCL calibration ...

Страница 21: ... and the sensor used immerse the sensing part of the sensor in the medium to be measured 4 Watch the display and wait for the reading to stabilize 5 By pressing the STO key you can hold and save a measured value see data logger page 22 Measurement can also be controlled via the Paraly SW 112 software Toggling between Compensated and Uncompensated Measured Values With temperature compensation TC ac...

Страница 22: ... a circular buffer Already existing entries will be overwritten The following data are recorded primary value temperature time stamp and device status The Paraly SW 112 software allows convenient management of the data logger It is always the currently selected process variable which is recorded The STO icon and the memory address is displayed briefly to indicate that an entry is being saved Data ...

Страница 23: ...ast recorded value 1 Manual logging when logger is deactivated Measurement Logger deactivated Measured value is maintained Proposed address blinks address of the last recorded value 1 If desired Select start address using st Measured value is saved to the desired address e g for overwriting an incorrect measurement Example Logger type INT Data Logger Interval INT In this mode the measured values a...

Страница 24: ...a Logger Example First entry 2 Delta 1 Delta Delta Delta Delta Delta Delta Delta Interval Difference Interval combined DIFF INT When the delta range related to the last DIFF entry is exceeded a new entry is created example entry A and the delta range is displaced upwards or downwards by the delta value As long as the measured value remains within the delta range logging is performed at the preset ...

Страница 25: ... h mm ss 0 00 01 9 59 59 0 01 00 DIFF INT DIFF See logger type DIFF INT See logger type INT SHOT Currently selected process variable is recorded Data Logger Menu Logger display Select using arrow keys confirm by pressing set CONT Select start address and start the data logger START Deletes all entries and starts the data logger at start address 0001 DEL Deletes all entries SET Select logger type a...

Страница 26: ...links Logger START blinks Logger DEL blinks Logger SET blinks Logger Current logger type blinks Select desired logger type using st DIFF INT DIFF INT or SHOT Select the appropriate parameters using st and confirm each selection by pressing set When configuration is finished CONT blinks You can start the data logger by selecting START or CONT see 27 ...

Страница 27: ...ue is saved to the selected start address exception SHOT FREE MEMORY is displayed LOGGER and active logger type icons are displayed Starting the Data Logger using START Prerequisite Data logger is configured All existing entries are deleted The start address for saving the values is 0001 Every time the meter has been switched off the data logger must be restarted exception SHOT Measurement Measure...

Страница 28: ...enient management of the data logger Measurement RCL The RCL icon and the last recorded value is displayed Use st to select the desired address Empty memory locations will also be displayed RCL or meas Return to measurement Data Logger Example Measured value stored at location 0026 Example Empty memory location 0004 ...

Страница 29: ...S SET All stored data are deleted 0000 DELETED is displayed Stopping the Data Logger You can stop the data logger at any time by pressing the meas key Measurement logger activated Data logger is stopped LOGGER and active logger type icons are no longer displayed It is still possible to hold a measured value by pressing STO and send it to any desired address Data Logger ...

Страница 30: ...lock proceed as follows Display of time date Hour display blinks SET HOUR Set value Minute display blinks SET MINUTE Set value Second display blinks and shows 00 Clock is started the seconds count up Year display blinks SET YEAR Set value Month display blinks SET MONTH Set value Day display blinks SET DAY Set value Display of corrected time date ...

Страница 31: ...ly when the Portavo USB port is connected to the computer The Paraly SW 112 software stands out by the following features Intuitive Windows user interface Easy configuration and management of several meters Display of device and sensor information Convenient management and evaluation of the data logger Export function for Microsoft Excel Print function Note A detailed user manual for the Paraly SW...

Страница 32: ...uest Measurement can still be performed After a calibra tion the corresponding Sensoface icon friendly neutral sad is shown togeth er with the calibration data Otherwise Sensoface is only visible in measuring mode The most important error messages and Sensoface info messages are shown on the inside of the protective cover A complete list of messages and their meanings is provided in the following ...

Страница 33: ...on the sensor condition Sensoface Meaning Sensor is okay Calibrate the sensor soon Calibrate or replace the sensor The neutral and sad Sensoface icons are accompanied by an INFO message to give a hint to the cause of deterioration Sensoface Message Cause INFO 6 Response time INFO 10 Polarization ...

Страница 34: ...r nominal cell constant or calibrate the sensor using a known solution ERROR 11 Measured value unstable Drift too high Leave the sensor in the liquid until the temperature is stable If this does not help replace the sensor ERROR 14 Time and date invalid Set time and date ERROR 18 Configuration invalid Restart reset to factory settings Setup DEFAULT YES configure and calibrate If this does not help...

Страница 35: ...er ZU 6985 Digital conductivity sensors Memosens 2 electrode sensor with graphite electrode and polysulfone body 120 mm NTC 30k SE 215 MS Temperature detectors Pt1000 temperature detector ZU 6959 Pt 1000 temperature detector with tilted tip ZU 0156 Memosens sensors have a cable coupling which allows convenient replacement of sensors while the cable remains connected to the meter Product Line ...

Страница 36: ...na plugs to the Portavo 904 COND ZU 0289 Adapter for connecting the ZU 6985 4 electrode sensor to the Portavo 904 COND ZU 0290 Please visit our website for more information on our product range www knick de Conductivity Standards for determining a cell constant Ready to use solutions Quantity Order No 15 µS cm 0 0001 mol l KCl 300 ml ZU 0350 147 µS cm 0 001 mol l KCl 500 ml ZU 0702 1413 µS cm 0 01...

Страница 37: ... 00 00 99 99 MΩ cm Salinity 0 0 45 0 g kg 0 30 C TDS 0 1999 mg l 10 40 C Temperature input Multicontact for sensors with integrated temperature detector or 2 x 4 mm dia for separate temperature detector Measuring ranges NTC30 temp detector 20 120 C Pt1000 temp detector 40 250 C Measuring cycle Approx 1 s Measurement error1 2 3 0 2 K Tamb 23 C TC 25 ppm K Sensor standardization CELL CONST Input of ...

Страница 38: ... calibration solution with simultaneous display of cell constant and temperature 0 01 MOL KCL 0 1 MOL KCL Automatic determination of the cell constant with KCl solution 0 01 mol l or 0 1 mol l Connections 1 x DIN socket 8 pins for analog sensors 2 x 4 mm socket for separate temperature detector 1 x M8 socket 4 pins for Memosens lab cable 1 x micro USB B for data transmission to PC Portavo 904 X Be...

Страница 39: ...s I Zone 0 AEx ia IIC T4 T3 Ta 40 C 50 C Entity Type 4X For electrical parameters and further specifications see Control Drawing No 209 009 110 RoHS conformity According to directive 2011 65 EU Power supply Portavo 904 Batteries 4 x AA alkaline or 4 x NiMH rechargeable or 1 x Li ion battery USB chargeable Portavo 904 X 4 x AA batteries For battery types see Control Drawing No 209 009 110 Operating...

Страница 40: ...ery compartment 13 Battery icon 14 Battery replacement 13 Benchtop stand 10 C Calibration 0 01 0 1 mol KCl 19 Calibration cell constant 18 Calibration COND 18 Calibration FREE CAL 20 cal key 12 CD ROM 7 Cell constant calibration 18 CELL CONST calibration 18 Certificates 7 Charge level of batteries 14 Clearing the data logger 29 Clock 30 clock key 12 Compensated measured values 21 COND calibration ...

Страница 41: ...ing 29 Data logger configuration 26 Data logger icons 22 Data logger menu 25 Data logger stopping 29 Data memory 22 Data of the meter 37 Date 30 Deleting data logger entries 29 Delta range data logger 24 Device configuration 17 Device messages 32 Device properties 8 Difference data logger mode 24 Difference Interval data logger mode 24 Digital sensors product line 35 Display 11 Display icons 16 Di...

Страница 42: ...ardous location batteries 14 Holding the measured value 23 Hook 10 Hours display 30 I Icons 16 Icons for data logger 22 IECEx 7 INFO messages 33 Inserting the batteries 13 Interrupting the data logger 29 Interval data logger mode 23 Introduction 8 K KCl solution 19 Keypad 12 L Li ion battery accessory 36 Lithium ion battery 13 Logger 22 Logger display 25 Logger type data logger modes 23 Index ...

Страница 43: ...ture of data logger 25 Messages 32 Micro USB port 15 Minutes display 30 O on off key 12 Operating modes of the data logger 23 Order numbers accessories 35 Overview 8 Overview of configuration 17 Overview of error messages 34 P Package contents 6 Panasonic Pro Power LR6 battery 14 Paraly SW 112 software 31 Parameter setting data logger 26 Parameter settings configuration 17 Portavo 904 X 13 Ports 1...

Страница 44: ...ently measured value 23 Seconds display 30 Sensoface messages 33 Sensor connection 15 Sensors 15 set key 12 Setting the configuration data 17 Setting the data logger 26 Setting the time and date 30 SHOT data logger mode 23 Smiley 33 Software Paraly SW 112 31 Specifications 37 Specific test report 7 Start address data logger 23 Starting the data logger using CONT 27 Starting the data logger using S...

Страница 45: ... Table of error messages 34 Table view of configuration 17 Technical data 37 Temperature class 14 Temperature detectors accessory 35 Temperature probe connection 15 Toggling between compensated and uncompensated values 21 Trademarks 3 Triangle icons 12 U Uncompensated measured values 21 USB port batttery 13 USB port micro 15 V Value added features 9 Viewing logger data 28 W Warranty 3 Index ...

Страница 46: ......

Страница 47: ......

Страница 48: ...9 4CD KNE01 20130102 Software version 1 x Knick Elektronische Messgeräte GmbH Co KG Beuckestr 22 D 14163 Berlin Phone 49 0 30 801 91 0 Fax 49 0 30 801 91 200 Internet http www knick de knick knick de 085133 ...