4.2 Output Wiring
The current measurement shown here
(3)
is for verifying the out-
put current without opening the output circuit. Terminals 3.1 and
3.3 are the monitor output.
The monitor output can be used for non-disruptive testing of the
output current by temporarily connecting a multimeter (to the test
jacks), or permanently connecting an isolated display unit.
An interruption in the monitor output, e.g., due to an open circuit,
will not result in impairment or failure of the primary current out-
put.