5
About This Manual
Subject to change without notice
Return of Products Under Warranty
Please contact our Service Team before returning a defective device.
Ship the cleaned device to the address you have been given.
If the device has been in contact with process fluids, it must be decontaminated/
disinfected before shipment. In that case, please attach a corresponding certificate,
for the health and safety of our service personnel.
Disposal
Please observe the applicable local or national regulations concerning the
disposal of “waste electrical and electronic equipment”.
About This Manual:
This manual is intended as a reference guide to your device –
You don’t have to read the book from front to back.
Take a look at the Table of Contents or the Index to find the function you are
interested in. Each topic is explained on a double-page spread with step-by-step
instructions on how to configure the desired function. Clearly legible page numbers
and headlines help you to quickly find the information:
58
59
Use of relays
Select process variable
Limit 1
switching characteristics (function)
Limit 1
contact type
Limit 1
setpoint
Limit 1
hysteresis
Limit 1
delay
Relay Contacts: Function Assignment, Limit Values
(Example: device type pH)
1 Press menu key.
2 Select CONF using
keys, press enter.
3 Select RELAY1 menu using
keys,
press enter.
Specify relay contact function: LIMIT.
4 All items of this menu group are indicated by the “LM1:“
code.
Press enter to select menu,
edit using arrow keys (see next page).
Confirm (and proceed) by pressing enter.
5 Exit: Press meas key until the [meas] mode indicator is
displayed.
4
Configuration: Relay Contacts
Menu item
Action
Choices
Use of relays
Select in the text line using
keys:
• Limit function (LIMITS)
• Error message (ALARM)
• Rinse contact (WASH)
Press enter to confirm.
Note: The following submenu
depends on the selected setting.
Select process variable
Select desired process variable
using
keys.
Press enter to confirm.
Limit 1 function
Select desired function using
arrow keys.
LoLevel: active if value falls
below setpoint
LoLevel: active if value exceeds
setpoint
Press enter to confirm.
Limit 1 icon:
Limit 1 contact response
N/O: normally open contact
N/C: normally closed contact
Select using
keys.
Press enter to confirm.
Limit 1 setpoint
Enter setpoint using
keys.
Press enter to confirm.
Configuration: Relay Contacts
Left page:
How do I get to the
function
Right page:
Which settings are pro-
vided for this function
Parameter concerned