Diaphragm Pump NMS 030
Technical data
KNF Micro BA306116-306115 NMS030-EN 0221
Operating and Installation Instructions
6
4. Technical data
General parameters
Parameter
Value
Allowed ambient temperature (°C)
+ 5 to + 40
Allowed medium temperature (°C)
+ 5 to + 40
Tab. 3
Pump Materials of gas-contacting parts
Type designation NMS030
KP
….
Components
Material
1)
Head plate; intermediate plate
PPS
Housing
PPS
Valve plate / seals
EPDM
Diaphragm
EPDM
Tab. 4
1) according DIN ISO 1629 and 1043.1
The pump type NMS030K_DC stands for
Motor voltage
12V
24V
Power consumption [W]
12
12
Max. I load [A]
1.00
0.50
Max. permissible current
consumption [A]
1.42
0.71
Connection [-]
Flat plug A 2.8x0.5.
Protection class [-]
IP00
IP00
Weight
1)
[g]
348
348
Delivery rate at atm. Pressure
[l/min]
2), 3)
11
Max. operating permissible
pressure [bar g]
0.2
Max. vacuum [mbar abs]
< 200
Tab.5
The pump type NMS030K_DCB (brushless) stands for
Motor voltage
12V
24V
12V-4
24V-4
Supply voltage [V]
12
24 10…28 10…28
Power consumption [W]
11
11
9.2
12
Max. I load [A]
0.91
0.46
0.80
0.50
Max. permissible current
consumption [A]
1.8
0.9
1.8
1.8
Lead size [-]
AWG 24
AWG 24
Protection class [-]
IP 54
IP 54
Weight
1)
[g]
218
218
218
218
Delivery rate at atm. Pressure
[l/min]
2), 3)
10.5
9.6
4)
12
5)
Max. operating permissible
pressure [bar g]
0.2
0.2
Max vacuum [mbar abs]
< 200
< 200
Tab.6
1)
The weight may differ slightly from the stated value, depending on the version.
2)
Depending on the application level (MASL), ambient temperature, material design
of the pump head and the connection hoses used, the flow rates may vary from the
values shown.
3)
Measured with air at 20°C / at atmospheric pressure
4)
At 5VDC
control voltage
5)
At 6VDC
control voltage