Diaphragm liquid pump NF 1.25
Technical data
KNF Flodos AG
BA_NF1.25_EN_03_163242
Translation of Original Operating and Installation Instructions, English
8
FG frequency output
FG pulses per mech. revolution
[ ]
6
Pulse length "low"
[%]
50
Output series resistance
[k
]
2.2
Output level 'high'
[V]
≥ 2.8
Output level 'low'
[V]
≤ 0.5
Tab. 8
In the case of type NF 1.25 DCB-4B the
supply voltage
is not
designed for operation with pulse-width modulated voltages
(PWM).
It is permissible to actuate the
control voltage
with a PWM
signal (frequency: 1 … 20kHz).
Electrostatic sensitive components (ESD)
Other parameters
Parameter
Value
Permissible
ambient temperature range [°C]
+ 5 to + 40
Permissible media temperature range [°C]
+ 5 to + 80
Permissible kinematic viscosity of medium
[cSt]
≤ 150
Tab. 9