Technical data
Diaphragm Vacuum Pumps N 813
6
Translation of original Operating and Installation Instructions, english, KNF 121240-121506 09/19
4. Technical data
N 813.3 ANE
Pneumatic performance
Max. permissible
operating pressure [bar g]
1
Ultimate vacuum [mbar abs.]
3
Flow rate at atm. pressure
[l/min]*
13
Pneumatic connections
Thread size
G 1/8
Ambient and media temperature
Permissible
ambient temperature
+ 5 °C to + 40 °C
Permissible media temperature
+ 5 °C to + 40 °C
Other parameters
Weight [kg]
5.9
Dimensions: L x H x W [mm]
approx. 230 x 148 x 140
Maximum permissible ambient
relative humidity
80 % for temperatures up to
31 °C, decreasing linearly to
50 % at 40 °C
Maximum altitude of installation
[m above sea level]
2000
Electrical data
Voltage / Frequencies
See type label
Max. operating current
Pump power
consumption
Maximum permissible mains
voltage fluctuations
+/- 10 %
Motor protection class
IP 44
Pump materials
Pump head
Aluminium
Diaphragm
EPDM
Valve
EPDM
Tab. 3
* liters in standard state (1013 mbar)
For pumps with thermo switch:
The pumps are fitted with a thermo switch to protect against over-
loading.
WARNUNG
Automatic starting can cause personal injury and
pump damage
When the operation of the pump is interrupted by the
thermal switch, the pump will restart automatically
after cooling down.
➔
Take all necessary care to prevent this leading
to a dangerous situation.
Thermo switch
Содержание N 813.3 AN.29DC-B