56
Figure 8-14
Machine data
Figure 8-15
Machine data “General”
8.7 Machine data
Access the sub-menu “F3 Machine data” (8-7/6) via the main menu “F5 Settings” (8-1/15). The
“Machine data” display (8-14) shows the basic machine settings. The data are saved in a file and
can be loaded again from the file.
1
“F1 Load from file”
2
“F2 Save as”
3
“F4 Apply value”
4
“F6 Back”: return to previous screen
8.7.1 General
“Coolant pump on”: true = always on,
false = only on at program start
“Waiting time after switching on coolant pump”:
(in secs)
8. Control system