Lerchenfeldstr. 9 87600 Kaufbeuren Phone: +49 (0)8341 9764-0 Fax: +49 (0)8341 67806
30
Battery monitor
The battery monitor (21) is integrated in the VB 06-1 junction box and protects
the supply battery (Battery 2) from damaging exhaustive discharge by low-
rating user.
Function
Permanent user with low current consumption, such as solenoid valves on
boilers, can cause the supply battery to discharge very slowly. Over a
prolonged period, this may lead to total discharge of the battery, making it
unusable. The battery monitor automatically monitors the battery voltage. It
actuates the ON/OFF outputs as a function of the main switch position and the
battery voltage.
Switching thresholds
Main switch
position
Battery voltage
Outputs
Delay
ON
11.0V or less
Switching off
3 minutes
ON
12.5V or more
Switching on
none
OFF
12.4V or less
Switching off
3 minutes
OFF
12.5V or more
Switching on
none