Lerchenfeldstr. 9 87600 Kaufbeuren Phone: +49 (0)8341 9764-0 Fax: +49 (0)8341 67806
27
Function
The junction box distributes the 12 V current and protects the circuits. Bord
Control 2005 effects control by means of the 12-pole control line (14). A
battery monitor, the function of which is described below, is integrated in the
junction box .
Minus connection
The screwed connection in the minus panel (13) is for fastening the minus
terminal cable. (see connection diagram)
Connection for BC 2005
The connection (14) establishes connection to the Bord Control via the 12-pole
jack.
Connection for PS
The side terminal (15) is for connection with the power supply.
Circuit 1
Circuit 1 (16) is being supplied when the main switch (13) is switched on. The
output marked with a * is being supplied when the main switch (13) is
switched on and the Circuit switch 1 (4) is actuated. This circuit provides six
contacts for flat push-on contacts 6.3mm wide and is protected with a 15A flat
push-on fuse.
Circuit 2, Water pump circuit
Circuit 2 (17) is being supplied when the main switch (13) is switched on. The
output for the water pump circuit marked with a * is being supplied when the
main switch (13) is switched on and the water pump circuit switch 5 is
actuated. This circuit provides six contacts for flat push-on contacts 6.3mm
wide and is protected with a 15A flat push-on fuse.
WC
The circuit (18) marked with a * is being supplied when the main switch (13)
is switched on and the switch for the vacuum WC (2) is actuated. This circuit
provides three contacts for flat push-on contacts 6.3mm wide and is protected
with a 10A flat push-on fuse.