background image

SmartMix
Instructions

V5350

Содержание SmartMix

Страница 1: ...SmartMix Instructions V5350...

Страница 2: ...CET Fax 49 30 8015010 Email support knauer net KNAUER Wissenschaftliche Ger te GmbH Hegauer Weg 38 14163 Berlin Germany Phone 49 30 809727 0 Fax 49 30 8015010 Internet www knauer net E Mail info knau...

Страница 3: ...tion 3 2 3 Operator responsibility 4 2 4 Personal safety equipment 4 2 4 1 General requirements 4 2 4 2 Contamination by health threatening solvents 5 2 4 3 Avoiding leakage 5 2 5 Specific environment...

Страница 4: ...tMix mixer 12 5 2 Exchanging the filter system 12 5 3 Replacing the cartridge 14 6 Troubleshooting 15 7 Transport and storage 15 7 1 Packing the device 15 7 2 Transporting the device 15 7 3 Storing th...

Страница 5: ...mmediate vicinity of the device and accessible to the user at all times You can download these and other instructions from the KNAUER web site www knauer net library 1 2 Signal words Possible dangers...

Страница 6: ...e you notice any damage inform the Technical Support and the shipping company within three workdays 1 4 3 Warranty conditions For information on warranty please refer to our general terms and condi ti...

Страница 7: ...the device Operation in potentially explosive areas without special and addition al explosion protection Contact the KNAUER Customer Support for more information 2 2 User qualification The users are...

Страница 8: ...ipment The protective measures required in the laboratory must be observed and the following protective clothing worn during all work on the device Safety glasses with side protection Protective glove...

Страница 9: ...Install capillaries and hoses in such a way that in case of a leak liquids cannot get into the interior of the devices underneath In case of leakage Switch off the system Only take the device into ope...

Страница 10: ...turer s instructions on caring for the columns see www knauer net columncare Used capillaries Do not use any used capillaries elsewhere in the system in order to avoid dead volumes not exactly fitting...

Страница 11: ...lid 3 Inlet to the pump 4 Mixer housing 5 Mounting boreholes 6 Cartridge inside the SmartMix 7 Outlet to the column Front view Fig 2 SmartMix mixer with cartridge 1 2 3 4 5 6 7 The SmartMix mixer con...

Страница 12: ...h versions can be used for pressures up to 1000 bar Wetted materials are stainless steel PEEK and Teflon To adapt the mixture volume two versions of cartridges can be inserted in the SmartMix mixer An...

Страница 13: ...e of stainless steel Two Phillips head screws Two washers Spare filter kit Three filter inserts PEEK sealing ring 3 4 Symbols and labels Explanations of symbols and labels on the system Symbol Explana...

Страница 14: ...ump head 7 Pressure sensor and venting valve 8 Mixing chamber 9 Capillary to tube Exterior view Fig 3 Mounting SmartMix mixer on the pump 1 2 3 4 5 6 7 8 9 1 Mount the SmartMix mixer to the front pane...

Страница 15: ...to the pump by the right inlet to the pump 2 on the mixer lid 3 3 Connect the capillary leading to the column with the outlet to the column 5 4 3 Installation in the HPG system For use in a high press...

Страница 16: ...2 Mixer lid 5 2 Exchanging the filter system Several filter inserts are inserted into the SmartMix mixer in a spe cific order They can be renewed as needed The SmartMix mixer has been removed The mix...

Страница 17: ...Insert the new fil ter system at position 1in the following order 1 unit filter sie ves 7 m 3 1 unit glass fiber filter 4 1 unit filter sie ves 3 m 5 Sequence filter inserts from top to bottom Fig 8 3...

Страница 18: ...t of the hous ing Otherwise the seals of the cartridge could be damaged 1 Loosen and lift off the mixer lid 2 Remove the PEEK sealing ring which is lying on the cartridge 3 Check the PEEK sealing ring...

Страница 19: ...carefully and safely packed for the transport into special shipping boxes 7 1 Packing the device Original packaging Ideally you should use the original transport packaging 7 2 Transporting the device...

Страница 20: ...le for the disposal of old devices as defined by the WEEE directive End users can send their old devices manufactured by KNAUER back to the distributor the importer or the company free of charge but w...

Страница 21: ...er 100 A5350 Analytical cartridge 350 l A5356 Micro cartridge 100 l A5355 Accessory kit SmartMix 1 filler cap made of stainless steel 2 Phillips head screws 2 washers F5351 SmartMix filter insert kit...

Страница 22: ...UER instructions online www knauer net library KNAUER Wissenschaftliche Ger te GmbH Hegauer Weg 38 14163 Berlin Phone Fax E Mail Internet 49 30 809727 0 49 30 8015010 info knauer net www knauer net KN...

Отзывы: