Decommissioning, transport and storage
If you plan to take the refrigerated island
out of service for an extended period of
time, follow these steps:
•
Remove all goods from the refrigera
-
ted island.
•
Turn off the refrigerated island.
•
Wait until the temperature of the ref
-
rigerated island has equalized to the
room temperature.
•
Clean all parts of the refrigerated
island as described in the chapters
„Cleaning“ and „Maintenance“. The
air circulation prevents unpleasant
odors and mold spores from forming
in the refrigerator compartment.
•
Make sure that the refrigerated island
is level during transport and that it
stands on all four feet securely.
•
Fasten the refrigerated island against
slipping when transporting it in a ve
-
hicle.
Improper storage can damage the
refrigerated island. Never leave the
refrigerated island in a place where it is
exposed to direct sunlight. The refrigera
-
ted island can be damaged by the high
temperatures.
Please note that disruptions to the Wurm
system will occur if you disconnect a
cooling island connected via a bus
connection from the mains by pulling the
mains plug out of the socket.
Productdetails and funcionality
This chapter provides information on the pro
-
duct details and functionality of the refrigera
-
ted island and the individual components that
are important for the proper handling of the
refrigeration island.
Climate class
Cooling devices must always correspond
to one of the climate classes 0 to 8 ac
-
cording to the ISO 23953-2 standard. The
climate class specifies specifications for
the environment in which the device is
operated. The cooling island is designed
as a device of climate class 3, for which
a maximum ambient temperature of
25°C and a maximum relative humidity
of 60% are specified. If the actual tem
-
perature and humidity values are above
the specified values, the energy efficien
-
cy of the cooling island may decrease.
If the actual values significantly exceed
the specifications, functional restrictions
of the refrigerated island are to be ex
-
pected.
Only operate the refrigerated island in
an environment that meets the require
-
ments of climate class 3.
Cooling unit
The refrigeration unit integrated in the
refrigerated island begins to work with a
delay of around 2 minutes after the ref
-
rigeration island is switched on. The refri
-
gerated island does not have a separate
on/off switch for the refrigeration unit, i.e.
by connecting the refrigerated island to
the mains you put it into operation at the
same time. Take all necessary prepara
-
tory measures before you connect the
cooling island to the mains (see chapter
Commissioning).
Housing and cooling storage
The refrigerated island is structured as
followed:
•
In the lower part „machine compart
-
ment“ is the cooling system and the
electrics.
•
The four outer panes of glass form the
perimeter of the cold room. Inside the
cold room is the goods space for the
display of the food to be cooled. This
is limited on both sides by the glass