![KMS Simplekey 4 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/kms/simplekey-4/simplekey-4_installation-manual_1979667040.webp)
Key Management Systems Ltd
40
|
P a g e
BUS Readers
Compatibility
BUS readers are only compatible with Simplekey 4 Controllers at version 3401 or higher.
BUS readers can work using KMS Sharktooth, Entrotag, PAC, Stanley and GDX proximity tokens
and cards.
Cabling
BUS readers MUST be wired using Cat5, Cat5e or Cat6 cable for optimum operation. Cable
should be pure copper, the use of CCS/CCA will degrade system performance. The maximum
cable run will vary on installation but 100m is nominal. Up to two BUS readers can be connected
to one Cat5e cable but please contact KMS Technical with specification of cable before
installation.
Installation
There are two types of BUS reader:
The Panel Mount BUS Reader is designed to fit within metal panels no thicker than 2.0 mm with
a 40mm square cut-out for the front of the reader to protrude through.
Stainless steel Vandal BUS Reader designed for surface mount on non-metallic surfaces.
Mounting on metallic surfaces may decrease reading range.
BUS readers come with a 0.5m flying lead Cat5 cable.
See wiring instructions on the following page.
Note:
BUS Readers are uniquely addressed using the 8-digit UDN, for
example 04000009. The reader will need to be assigned to a door by
KMS, up to two readers can be assigned to any one door.
Connection
KMS provide a dedicated connector to wire all
BUS readers into the system. This is known as an
RJ45 BUS Adaptor.
M2S S2MMODE 0V
12V
0V
KMS LTD SK4
RJ45 BUS ADAPTOR
ISSUE 05 © 2018
To BUS Reader(s)
To system
connections