AppStat For Fan Coil Units

4

919-019-01B

Maintenance

Remove dust as necessary from the holes in the top
and bottom. Clean the display with soft, damp cloth
and mild soap.

Specifications

AppStat specifications are subject to change without
notice.

Supply Voltage

24 volts AC (–15%, +20%),
50-60 Hz, 12 VA,
Class 2 only

Inputs

0–12 volts DC with internal 10kΩ
pull-up resistors

Relay outputs

SPST, 24 volts, 1 amp AC or DC
Maximum for all relay outputs is
3 amps

Analog outputs

Short protected 10mA 0–12 VDC

Environmental
limits

Operating 34 to 125° F (1.1 to
51.6° C)
Shipping –40 to 140° F
(–40 to 60° C)
Humidity 0 to 95% RH
(non-condensing)

Regulatory

UL 916 Energy Management
Equipment
FCC Class B, Part 15, Subpart B
and complies with Canadian
ICES-003 Class B

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.

Installation accessories

The following accessories are available from KMC
Controls, Inc.

XEE-6111-040 Single-hub 120 volt power

transformer

XEE-6112-040 Dual-hub 120 volt power

transformer

XEE-6311-075 120/240/277/480VAC, 24 VAC, 75 VA

transformer

HMO-10000W White mounting plate kit for retrofit

on horizontal boxes or 4 x 4 handy
boxes

Additional resources

The latest support files are always available on the
KMC Controls web site.

For detailed specifications, installation, operating ,
application, and system integration information, see

The Installation, Operation, and Application Guide
for AppStat

.

For additional specifications information, see the

BAC-4000 AppStat Data Sheet

.

Important Notices

The material in this document is for information
purposes only. The contents and the product it
describes are subject to change without notice. KMC
Controls, Inc. makes no representations or
warranties with respect to this document. In no
event shall KMC Controls, Inc. be liable for any
damages, direct or incidental, arising out of or
related to the use of this document.

KMC Controls, Inc.

P.O. Box 497
19476 Industrial Drive
New Paris, IN 46553
U.S.A.
TEL: 1.574.831.5250
FAX: 1.574.831.5252
E-mail: [email protected]

Содержание AppStat

Страница 1: ...e surface temperature of the object and the background temperature of the room is too small Object movement in a direct line toward the sensor Very slow or very fast object movement Obstructions as shown in the illustration Typical motion sensing coverage area on page 1 False detections may be triggered by The temperature inside the detection range suddenly changes because of the entry of cold or ...

Страница 2: ...the mounting base 4 Position the base with the embossed UP toward the ceiling and fasten it directly to a vertical 2 x 4 inch electrical box For horizontal boxes or 4 x 4 applications use a wall plate kit See Installation accessories on page 4 for part numbers 5 Connect the wires for the AppStat to the terminals in the mounting base 6 Place the top of the sensor over the top of the mounting base a...

Страница 3: ...on Follow the instructions supplied with the sensor for installation Connecting outputs The AppStat outputs are model dependent and are configured for specific applications No field programming or set up is required or possible Depending on model and application the AppStat outputs are designed for either 24 volt AC or 0 10 volt DC loads The outputs may represent analog or digital signals Caution ...

Страница 4: ...ion Installation accessories The following accessories are available from KMC Controls Inc XEE 6111 040 Single hub 120 volt power transformer XEE 6112 040 Dual hub 120 volt power transformer XEE 6311 075 120 240 277 480VAC 24 VAC 75 VA transformer HMO 10000W White mounting plate kit for retrofit on horizontal boxes or 4 x 4 handy boxes Additional resources The latest support files are always avail...

Отзывы: