32
Example:
In this condition...
...if wanting to control boiler with KLOVER remote control room temperature only, I must:
enable room probe on remote control (stove settings menu +> Enable room probe -> ON)
disable boiler thermostat contact on boiler display (menu 4 enable contact -> OFF)
In this case, the boiler firstly enters functioning economy and then automatically switches off when room
temperature (detected with KLOVER remote control) is satisfied.
...if wanting to control boiler with KLOVER remote control room temperature and with boiler thermostat, I
must:
enable room probe on remote control (stove settings menu +> Enable room probe -> ON)
enable boiler thermostat contact on boiler display (menu 4 enable contact -> ON)
In this case, the boiler firstly enters functioning economy and then automatically switches off when both
temperatures are satisfied.
...if wanting to control boiler with boiler temperature only, I must:
disable room probe on remote control (stove settings menu +> Enable room probe -> OFF). The room
probe is automatically disabled if external remote control is not connected.
enable or disable boiler thermostat contact on boiler display (menu 4 enable contact -> ON/OFF)
In this case, the boiler firstly enters functioning economy and then automatically switches off when boiler
temperature (detected with external thermostat immersed in boiler) is satisfied. This may be a good solution
to heat DHW during the summer period.
...if not wanting to control boiler with external thermostats but with heating system water temperature only, I
must:
disable room probe on remote control (stove settings menu +> Enable room probe -> OFF). The room
probe is automatically disabled if external remote control is not connected.
enable or disable boiler thermostat contact on boiler display (menu 4 enable contact -> ON/OFF). The
contact must be bridged (done in factory).
Only upon reaching of temperature set in
“SET H2O”
or
“SET DHW”
does the boiler enter functioning
economy.