13
REQUISITES OF THE PLACE OF INSTALLATION
Positioning
The initial phase for the best installation of the boiler is to determine its optimal location; the following
data needs to be considered for this:
An external air vent can be made;
A straight flue and possibly coaxial at the boiler outlet can be made;
Proximity to the main liquid collector and /or the boiler if one already exists);
Proximity or ease of connection to the water system;
Ease of access for cleaning the boiler, the flue gas exhaust pipes and the flue.
The boiler must be installed on a floor with suitable load capacity. If the existing building does not
fulfil this requirement appropriate measures (e.g. load distribution plate) must be taken.
Once the best location for the appliance is determined, it is possible to position the boiler, following
the indications below.
The minimum safety distance from flammable materials must be at least 200 mm from the sides
and back of the boiler.
Spaces around and above the boiler
The figure below indicates the minimum measurements to respect when positioning the boiler
according to the walls.
PARETE POSTERIORE
PAR
E
T
E
L
AT
ER
AL
E
PAR
E
T
E
L
AT
ER
AL
E
50 cm
50 cm
15 cm
Any shelves or suspending ceilings assembled above the boiler must be at least 40 cm away from its
upper part.
External air vent
While it is running the boiler withdraws air from the environment in which it is installed
; it is
essential that the air is restored through an external air vent.
If the wall behind the boiler is an outside wall, drill a 15 cm diameter hole at 20 cm from the ground
(as Fig. A).
Furniture and mobile objects must be positioned at least 15 cm from the boiler side walls; these
objects must be moved when servicing the boiler.
It is forbidden to hang shelves or build suspended ceilings above the boiler at a distance measuring
less than 40 cm.
Protect all structures that can catch fire from heat radiation.
The hole must be protected externally with a fixed grid.
Periodically ensure the grid is not
obstructed by leaves or similar, thus blocking the air passage.