DIVA SLIM AIR PELLET STOVE
42
EN - Rev. 1.0
Parameter tables DIVA SLIM MULTI-AIR
“CLEANER SETTINGS” parameters - Model DSC
(L15_181119)
Parameter
Menu level
Description
Display
Measurement
Value field
Database
P2
Pr51
M10 – 01 – 01
ON time for brazier cleaning gear motor
CLEANING TIME
Seconds
0 – 120”
13
Pr52
M10 – 01 – 02
Time from switching off after which the brazier cleaning cycle starts
CLEANER DELAY
Minutes
1 – 15
6
Pr53
M10 – 01 – 03
Time from switching on after which the brazier cleaning cycle starts
CLEANER STAND-BY
Hours
1 – 24
9
“DUCTING SETTINGS” parameters - Model DSC
(L15_181119)
Parameter
Menu level
Description
Display
Measurement
Value field
Database
P2
Pr55
M10 – 03 – 01
Enables ducting operation
ENABLE DUCT.
Off / Mode
Off
S1 – S2 – S1+2
T1 – T2 – T1+2
A1 – A2 – A1+2
A1
Pr56
M10 – 03 – 02
Allows for choosing whether the ducted air fans can be switched “OFF”.
DUCTED OFF
On – Off
On – Off
Off
Pr57
M10 – 03 – 03
Heat exchanger 2 (ducting 1) in power 1 work phase
DUCT.1 SPEED-S1
Volt
65 – 225
165
Pr58
M10 – 03 – 04
Heat exchanger 2 (ducting 1) speed in power 2 work phase
DUCT.1 SPEED-S2
Volt
65 – 225
175
Pr59
M10 – 03 – 05
Heat exchanger 2 (ducting 1) in power 3 work phase
DUCT.1 SPEED-S3
Volt
65 – 225
190
Pr60
M10 – 03 – 06
Heat exchanger 2 (ducting 1) in power 4 work phase
DUCT.1 SPEED-S4
Volt
65 – 225
220
Pr61
M10 – 03 – 07
Heat exchanger 2 (ducting 1) in power 5 work phase
DUCT.1 SPEED-S5
Volt
65 – 225
225
Pr62
M10 – 03 – 08
Heat exchanger 3 (ducting 2) in power 1 work phase
DUCT.2 SPEED-S1
Volt
65 – 225
65
Pr63
M10 – 03 – 09
Heat exchanger 3 (ducting 2) in power 2 work phase
DUCT.2 SPEED-S2
Volt
65 – 225
65
Pr64
M10 – 03 – 10
Heat exchanger 3 (ducting 2) in power 3 work phase
DUCT.2 SPEED-S3
Volt
65 – 225
65
Pr65
M10 – 03 – 11
Heat exchanger 3 (ducting 2) in power 4 work phase
DUCT.2 SPEED-S4
Volt
65 – 225
65
Pr66
M10 – 03 – 12
Heat exchanger 3 (ducting 2) in power 5 work phase
DUCT.2 SPEED-S5
Volt
65 – 225
65
Parameters “VARIOUS SETTINGS” - Mod. DSC
(L15_181119)
Parameter
Menu level
Description
Display
Measurement
Value field
Database
P2
Pr38
M10 – 04 – 01
Re-ignition block
RESTART BLOCK
Minutes
0 – 10
5
Pr39
M10 – 04 – 02
Time for considering the device off
OFF TIME
Minutes
0 – 20
10
Pr40
M10 – 04 – 03
Pre-loading time in ignition
PRE-LOAD START
Seconds
0 – 255
210
Pr41
M10 – 04 – 04
Stand-by time after pre-loading
AFTER PRE-LOAD
Seconds
0 – 255
120
Pr42
M10 – 04 – 05
Extractor speed in pre-loading phase
PRE-LOAD SMOKE
SPEED
Rpm
350 – 2800
2100
Pr43
M10 – 04 – 06
Temperature delta on “SET ROOM” for automatic switching on/off
DELTA ON-OFF
°C
0.0 – 10.0
1.0
Pr44
M10 – 04 – 07
Automatic switch-off delay (timer after reaching “SET ROOM”)
AUTO OFF DELAY
Minutes
2 – 120
10
Pr45
M10 – 04 – 08
Power change delay
POWER CHANGE
Seconds
0 – 240
60
Pr46
M10 – 04 – 09
Heat exchanger 1 speed (primary) in the switch-off phase
AIR SPEED OFF
Volt
65 – 225
225
Pr47
M10 – 04 – 10
Keypad lock enable
KEY LOCK
On – Off
On – Off
Off
Pr48
M10 – 04 – 11
Time after which an alarm is triggered in the event of a blackout
BLACK OUT TIME
Seconds
0 – 60
30
Pr49
M10 – 04 – 12
Time after which the “NO PELLET” alarm triggers In case of “PELLET
RESERVE”
RESERVE ALARM
Minutes
1 – 180
60
Pr50
M10 – 04 – 13
Enabling of the pellet level sensor (only on configured models)
PELLET RESERVE
On – Off
On – Off
Off
Содержание DIVA SLIM
Страница 1: ...ENGLISH DIVA SLIM AIR pellet stove INSTALLATION USE MAINTENANCE AND HELPFUL TIPS ...
Страница 2: ......
Страница 9: ...DIVA SLIM AIR PELLET STOVE 7 EN Rev 1 0 Overall dimensions ...
Страница 49: ...DIVA SLIM AIR PELLET STOVE 47 EN Rev 1 0 ...
Страница 50: ...DIVA SLIM AIR PELLET STOVE 48 EN Rev 1 0 ...
Страница 51: ...DIVA SLIM AIR PELLET STOVE 49 EN Rev 1 0 ...
Страница 52: ...Code CS IST DSA EN KLOVER Srl Via A Volta 8 37047 San Bonifacio VR VAT No 02324280235 www klover it ...