16
WHAT HAPPENS IF..
…the pellet does not ignite
With no ignition. The
“NO IGNIT“
alarm message appears.
Cancel the alarm and bring the stove to standard condition by pressing key 4 for a few seconds.
...the fire door is open or closed improperly
In case the door is open or closed improperly, the motor reducer cannot be powered electrically, not allowing the stove to switch on. If the fire door is
opened during the normal functioning, the stove burns all the pellet in the brazier, activating the
“NO PELLET”
alarm (sudden switch off).
...the flue is dirty, blocked or not manufactured correctly
In case the flue is dirty, blocked or not manufactured correctly, the motor reducer cannot be powered electrically not allowing the stove to switch on. If the
flue blocks during the normal operation, the stove burns all the pellet in the brazier, activating the
“NO PELLET”
alarm (sudden switch off).
…the pellet tank goes in over-temperature
The motor reducer is not electrically powered with pellet tank over-temperature as the thermostat intervenes in manual re-arm. If it happens with stove
working, the latter goes in
“NO PELLET”
alarm (sudden switch-off). Therefore the thermostat must be rearmed before switching on the stove.
...lack of power (black out)
Upon restore after power outage due to time less than Pr48, the stove immediately re-starts from operative state it had before power outage (recovering the
set work power).Upon restore after power outage due to time more than Pr48, the stove sets on
“STOP FIRE” (stand-by)
mode and carries out the entire
switch off cycle until its cooling. Once this phase is completed, the thermo stove can be normally switched on to proceed working at the set power.
Previous state
Black-out duration
State after power restore
OFF
Any
OFF
START
duration < Pr48
START
START
duration > Pr48
START
LOAD PELLET
Any
BLACK OUT ALARM
WAITING FIRE
Any
BLACK OUT ALARM
FIRE ON
duration < Pr48
FIRE ON
FIRE ON
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
WORK (any phase)
duration < Pr48
WORK (any phase)
WORK (any phase)
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
BRAZIER CLEANING
duration < Pr48
BRAZIER CLEANING
BRAZIER CLEANING
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
FINAL CLEANING
duration < Pr48
FINAL CLEANING and after cooling
OFF
FINAL CLEANING
duration > Pr48
FINAL CLEANING and after cooling
OFF
STOP FIRE
Any
STOP FIRE
CIRCUIT BOARD PARAMETERS
THE PARAMETERS MEMORISED ON THE CIRCUIT BOARD ARE FUNDAMENTAL FOR THE CORRECT FUNCTIONING OF THE STOVE.
THE PARAMETERS GIVEN BELOW ARE ALREADY MEMORISED IN THE STOVE INSPECTION PHASE DIRECTLY IN THE FACTORY.
THESE PARAMETERS ARE THE RESULT OF CAREFUL TESTS WITH VARIOUS TYPES OF PELLETS AND MUST NOT BE CHANGED WITHOUT
THE AUTHORISATION OF KLOVER srl, SO AS NOT TO JEOPARDISE STOVE FUNCTIONING.
ALL RESPONSIBILITIES ARE DECLINED FOR DAMAGE CAUSED BY INCORRECT INTRODUCTION OF THE PARAMETERS.
“Various calibrations” (Menu M – 9 – 5)
Parameter
Menu level
Description
Display writing
Measurement
Value field
Database
Pr38
M
– 9 – 5 – 01
Re-ignition block
RE-IGNIT BLOCK
Minutes
0
– 10
5
Pr39
M
– 9 – 5 – 02
Flue gas intake device switch-off time
MIN-INT OFF
Minutes
0
– 20
10
Pr40
M
– 9 – 5 – 03
Pre-load time in ignition
IGNIT PRE-LOAD
Seconds
0
– 225
95
Pr41
M
– 9 – 5 – 04
Stand-by time after pre-load
AFTERPRE STANDBY
Seconds
0
– 255
170
Pr42
M
– 9 – 5 – 05
Intake device speed in pre-load phase
EXHMOTOR PRELOAD
Revs/min
500
– 2800
2200
Pr43
M
– 9 – 5 – 06
ON/OFF temperature hysteresis
“SET ROOM”
DELTA ON OFF AUTO
°C
0
– 15
2
Pr44
M
– 9 – 5 – 07
Delay to economy switch-off (timer after
reaching
“SET ROOM” + Pr43
)
DELAY OFF AUTO
Minutes
2
– 120
2
Pr45
M
– 9 – 5 – 08
Power change delay
POWER CHANGE
Seconds
0
– 60
30
Pr46
M
– 9 – 5 – 09
Exchanger 1 motor speed in switch-off phase
AIR IN OFF
Volt
65
– 225
225
Pr47
M
– 9 – 5 – 10
Keypad block enabling
KEYS BLOCK EN
On
– off
On
– off
OFF
Pr48
M
– 9 – 5 – 11
Automatic re-ignition after black-out
BLACK OUT IGNITION
Seconds
0
– 60
30
Pr49
M
– 9 – 5 – 12
Room probe calibration
ROOM-T OFF-SET
°C
- 9
– 9
0
Содержание DEA PLUS