5.2.7.4.6 V. FLOW L/h
Display the lower and upper volume range value.
5.2.7.4.7 DENSITY kg/m
3
Display the lower and upper density range value.
5.2.7.4.8 TEMP
℃
Display the lower and upper temperature range value.
5.2.7.4.9 ERROR #
When the flow meter is not under normal condition, the code found here may provide
valuable troubleshooting information.
5.2.8 SERVICE
5.2.8.1 In the “SERVICE” of secondary interface, press “FUNC” to enter the third level interface.
5.2.8.2 After entering the third level interface, press “UP” or “DOWN” to select specific setting
items, and press “FUNC” to enter setting information, press “UP” or “DOWN” to change
parameter, press “FUNC” to confirm, and press “ESC” to exit.
5.2.8.3 SERVICE third level interface.
The service menu contains information that is useful for service training. The contents of
the menu are as follows.
5.2.8.3.1 RAW DATA
5.2.8.3.1.1 View the original data of flowmeter.
5.2.8.3.1.2 Viewable parameters include Frequency, Phase, Zero point, Filter parameters,
Phase difference
5.2.8.3.1.2.1 Frequency: current vibration frequency of flow tube.
5.2.8.3.1.2.2 Phase: the current phase value of the sensor.
5.2.8.3.1.2.3 Zero point: the current zero point phase value of the sensor.
5.2.8.3.1.2.4 Filter parameters: the current filter coefficient.
5.2.8.3.1.2.5 Phase difference: phase difference = phase-zero.
5.2.8.3.2 REAL LOOP V
5.2.8.3.2.1 Display the voltage of pick coil.
5.2.8.3.2.2 The left value is upstream pickup coil voltage.
5.2.8.3.2.3 The right value is the downstream pickup coil voltage.
5.2.8.3.3 OUTPUT TEST
5.2.8.3.3.1 Simulate the output signal & test whether the flow meter output signal is right.
5.2.8.3.3.2 A total of 5 test points: 0%, 25%, 50%, 75% & 100%.
5.2.8.3.4 CLR ERROR
Clear ERROR alarm code.
5.2.8.3.5 REBOOT
Reset the flow meter with power on.