Wiring
3.1
Integral SCM wiring
3.1.1 Internal wiring
For SCM with integral transmitters, wiring between sensor & transmitter is complete before it
leaves the factory.
3.1.2 T0 Version transmitter
3.1.2.1 The transmitter’s terminal layout is detailed in Figure 3-1, and the terminal
functions are defined by Table 3-1.
(
Analog Loop 2 is not default option
)
Figure 3-1 T0 version transmitter terminal layout
Table 3-1 T0 version transmitter terminal description
Power Supply
ACL/DC+
Live / Positive
Confirm range against
nameplate
ACN/DC-
Neutral/Negative
Ground
Ground
Frequency output
Freq+
Positive frequency out
0 to 10kHz
Freq-
Negative frequency out
RS485 (MODBUS)
RS485A
Modbus terminal A
RS485B
Modbus terminal B
Analog Loop 1
A1+
Positive analog out 1
4 to 20mA
A1-
Negative analog out 1
Analog Loop 2
A2+
Positive analog out 2
A2-
Negative analog out 2
3.1.3 T1 version transmitter
3.1.3.1 The transmitter’s terminal layout is detailed in figure3-2, and the terminal
functions are defined by figure 3-3.
(
Analog Loop 2 is not default option
)