4
Filtering unit
UFO-A-5000 24.05.2019
2. Application
UFO-A-5000
filtering unit is manufactured in two versions
UFO-A-5000 RH
with the air outlet
on the right side and
UFO-A-5000 LH
with the air outlet on the left
.
The device is designed for
cleaning the
air
from the impurities arising
during manufacturing processes. The appliance is
used for removal of
dry
dust
particles
(
without aggressive compounds or impurities creating
explosive hazard
)
arising during welding,
grinding of non-sparking materials, gas- or plasma
metal cutting or during other dust-generating processes in following industries as chemical
pharmaceutical, plastic-, food production and in other lines.
The device is equipped with cartridge filters with polyester fabric,
capturing the dust particles
at the
outer
surface of the filter.
The filter regeneration system shakes cyclically the impurities
from the filter surface
(by means of compressed air). The maximum admissible temperature
of the conveyed air is 60ºC
3. Reservations of Producer
Manufacturer accepts no liability for any damages in case of occurrence of one of the
below mentioned causes
:
A
.
Improper installing that is in contradiction with the present Use and Maintenance Manual.
B
.
Incorrect connection to the power supply
(energising)
or to the external compressed air in-
stallation.
C
.
Operational use
that is in contradiction with the present Use and Maintenance Manual or
with the valid regulations.
D
.
Installing of any additional elements
that are not belonging to the original
device structure
or accessory set.
E
.
Structural changes or modification
of the appliance,
carried out on one’s own or
use of not
original spare parts, not purchased at the manufacturer’s.
F
.
Situations where the rules of technical supervisions and maintenance are not observed,
according to the present Use and Maintenance Manual.
G
.
Forwarding the air containing viscous and aggressive contamination,
as this would cause
damage of filters, or conveying the air of temperature higher than 60
ºC.
H
.
In the course of
operational use, pay attention that
any ignition sources,
i.e. glowing
cigarette butts / embers must not get into the filtering chamber.
4. Technical Data
Table No.1
Type
Maximum
volume
flow
Maximum
vacuum
Motor
rate
Supply
voltage
Quantity
of the
cartridge
filters
Acoustic
pressure
level
Consum-
ption of the
compressed
air
Weight
[m
³/h]
[Pa]
[kW]
[V/Hz]
[pcs]
[dB(A)]
[Nm
³/h]
[kg]
UFO-A-5000 RH
6300
4100
5,5
3x400/50
2
72
2,8
610
UFO-A-5000 LH
Cartridge filters: quantity
–
2 pcs
diameter
–
Ø380 mm
height
–
660 mm