20
Filtering unit
UFO-A-5000 24.05.2019
Cons
. STOP = OFF
Cons
. REGEN = OFF
Screen MODES 5/6
[Cons. STOP]:{
OFF
I
ON
}
OFF
– blocking the possibility of stop, by means of the
input
DI5
of the status
NSTR
ON
– stop of the status z
NSTR
active
Input
DI5
realises the same function as the button
STOP
S2
on the elevation console
[Cons. REGEN.]:{
OFF
I
ON
}
OFF
– blocking of the possibility of activation of filters regeneration, by
means of the input
DI6
ON
– the operated regeneration is active
Input
DI6
fulfils the same function as the button
FILTER
S3
on the
elevation console
DI8
START = OFF
DI8
STOP = OFF
Screen MODES 6/6
[
DI8
START
]{
OFF
I
ON
]
OFF
– blocking of the possibility of activation, by means of the input
DI8
of the state
NSTR
(switching on within the level)
ON
– switching on the status
NSTR
active (switching on within the level)
[
DI8
. STOP]:{
OFF
I
ON
}
OFF
– blocking the possibility of switching off, by means of the input
DI8
of the status
NSTR
(switching on within the level)
ON
– stop of the status
NSTR
active (switching on within the level)
In case when [
DI8
.
START
]=
ON
and [
DI8
stop]=
ON
input
DI8
fulfils the
function of remote control
ON
/
OFF
of the status
NSTR