Filtering unit

 

  UFO-A-5000                                     24.05.2019 

   

 

 

At 

the moment when the suction

 volume capacity evidently drops, and it keeps low level 

for a longer time, take out the filters and clean them manually 

(

with compressed air

)

 

Additionally, undertake control 

when the device

 is functioning incorrectly in another way. When  

the

 cartridge filters are damaged of naturally worn out, replace them for new ones. While repla-

cing,  put the filters subsequently  on the guide profiles  and push them tightly to the wall of the 
electro-valves chamber.

  

Subsequently tighten the filters  with a profile straps and screw knobs.  

Close tightly the door of the chamber of filters and tighten up the screw locks of the door.   
Having replaced the filters connect the device to the power supply again. 
Upon 

normal functional

 wear out, 

the cartridge

 filters must be replaced after 1 to 2 years of ope-

rational use. 

 

9.2  Fan 

After every year 

of operational

 

use

 

– clean and examine the impeller, the state of the fan motor  

itself,  according to the instructions  of the motor manufacturer.  In case of incorrect function of  
the fan, 

contact

 with the manufacturer. 

When it is necessary to

 

replace the

 fan or the motor, this  

can be executed exclusively by a specialised team. 

 

9.3  Compressed air tank 

The

 compressed air tank 

should

 be examined and submit to maintenance 

– 

according to

 the re-

gulations on pressure devices. Periodically, check all the connections applied on the tank, and 
make dewatering 

through the drainage fitting piece that is installed for

 this purpose at the bottom  

part of the tank. 

 

9.4  Electromagnetic valves 

The applied electromagnetic valves do not require current maintenance. It is sufficient to check  
the state of electrical connections,  the state of grounding and tightness of the pneumatic instal- 
lation.  It is recommended

  

to replace the valves after 2 years of use,  but not later than 4 years.   

For this purpose contact the manufacturer of the filtering unit. 

 

9.5  Pneumatic silencers 

On the 

electromagnetic

 valves are p

laced pneumatic silencers 3/8” to reduce the noise level du- 

during the compressed air “shot”.  
After two months of use,

  

the silencers must be disassembled and cleaned.  For control periods  

see Table below. 

 

9.6  Suggested periods of control and maintenance of  the filtering unit 
Table No.4 

Current control of the function after the 
waste container is filled up. 

Empty the container from the deposited dust. 

Routine (current) control 

Systematically clean the device and assemblies, so 
the dust particles would not deposit on the ele-ments. 

Upon each emptying of the waste container  Check visually the cartridge filters, through the door  

of the chamber of filters. 

Every 2 months 

Clean the pneumatic silencer (located on the electro-
magnetic valve) 

– soak in the extraction naphtha and 

clean it. 

Once a month 

Examine the state of the device grounding and check 
the conductivity between all the assemblies of the 
filtering unit. 

Every 2 

÷ 3 months 

General visual inspection of the supporting structure 
and the housing, check the screw connections. 

Every 12 months 

Examine the state of electrical connections and  
the installation of the compressed air, the 
connections of the electromagnetic valves. 

 

 

Содержание UFO-A-5000

Страница 1: ...1 24 05 2019 Filtering unit UFO A 5000 Use and Maintenance Manual Filtering unit UFO A 5000...

Страница 2: ...rvations of Producer 4 4 Technical Data 4 5 Structure and Function 6 6 Assembly and Start up 9 7 Operational Use 12 8 Troubleshooting Guide 27 9 Maintenance 27 10 Occupational Health and Safety 29 11...

Страница 3: ...the making available on the market of electrical equipment designed for use within certain voltage limits Journal of Laws EC L96 of 29 03 2014 The appliance meets the requirements included in 2009 125...

Страница 4: ...contradiction with the present Use and Maintenance Manual B Incorrect connection to the power supply energising or to the external compressed air in stallation C Operational use that is in contradicti...

Страница 5: ...ed air minimum 0 6 MPa capacity of the waste container 72 dm3 connection to the compressed air diameter 12 mm quick connector Fig No 1 Flow chart Table No 2 Replaceable parts Cartridge filter 2 pieces...

Страница 6: ...for the fan function as des cribed in details in Section 7 In the filtration chamber is formed a separate regeneration chamber where are introduced outlets of the filters and Venturi orifices There ar...

Страница 7: ...tainer for dust capacity 72 dm3 As additional equipment upon separate order the device can be equipped with a fan cover installed on the device see Fig No 2 Filtering units with a free not plugged ou...

Страница 8: ...8 Filtering unit UFO A 5000 24 05 2019 Fig No 3b UFO A 5000 LH with the air inlet on the left side dimensions...

Страница 9: ...ating profile 6 Assembly and Start up 6 1 Assembly description UFO A filtering unit is designed for installing inside the rooms indoor application In case of outdoor application it is important to app...

Страница 10: ...the supply system This ought to be carried out exclusively after the device is disconnected from the power supply system To load or replace the cartridge filters open the front door of the chamber of...

Страница 11: ...UFO A 5000 2 On demand of Customer the filtering unit can be equipped with an activated carbon impreg nated nonwoven spunbond filter for filtering the gases arising during welding processes Fig No 5 C...

Страница 12: ...amp H3 alarm blinking light during the emergency after confirmation by pres sing the S2 STOP button the lamp lights continuously until the mo ment when the failure is fixed Press the S2 STOP button on...

Страница 13: ...13 24 05 2019 Filtering unit UFO A 5000 Fig No 6 Switchgear front Fig No 7 Control panel...

Страница 14: ...and not complete phases function effects over current disconnector F1 protection for the transformer circuit and the controller over current disconnector F2 protection for the circuit of the electrom...

Страница 15: ...he menu How to change the editable parameter OK marking illumination of the parameter RIGHT LEFT displacing the cursor between the fields that are possible to be marked UP DOWN change the value of the...

Страница 16: ...ion stage of the filters STOP the device is being stopped after the alarm vanishes operator needs to delete it ALPR1 alarm signal of low pressure 1 ALPR2 alarm signal of low pressure 2 ALPR3 alarm sig...

Страница 17: ...Sub menu of the settings COMMUNICATION 1 The function is not active in the program version 2 0 up to 2 2 INPUTS OUTPUTS Screen INPUTS OUTPUTS Sub menu of the settings INPUTS OUTPUTS Day Tu hour 10 00...

Страница 18: ...ctivated initial regeneration SWF TEMP REG NONE AL24V akt OFF Screen MODES 2 6 TEMP REG NONE I HEAT I COOL NONE disconnected the controlling with output OUT5 in function of temperature HEAT activated...

Страница 19: ...he status at inputs DI0 up to DI3 ALPR akt OFF Cons START OFF Screen MODES 4 6 ALPR AKT OFF and ON OFF blocking of the occurring alarm ALPRi at the inputs DI0 up to DI3 ON alarm ALPRi at the inputs DI...

Страница 20: ...ve Input DI6 fulfils the same function as the button FILTER S3 on the elevation console DI8 START OFF DI8 STOP OFF Screen MODES 6 6 DI8 START OFF I ON OFF blocking of the possibility of activation by...

Страница 21: ...ctro magnetic valves during the status SWF Lsekwen Lon 0 9 cycles Lsekwen Lon number of sequences 4 cycles of pulsing each Time T12 0 5s Ton PowPause 10s Screen SETTINGS 2 6 Time T12 0 1 5 sec Time T1...

Страница 22: ...ectromagnetic valves StanZas 24V state of the fuse of the transformer 24VAC of the power supply of the electromagnetic valves Time T22 0 5s Lsekwen Loff 02 Screen SETTINGS 4 6 Time T22 1 99sec Time T2...

Страница 23: ...ion of the signal from the inputs of the pressure control within the circuit of the electro valves AktPoziomWe LO I HI AktPozimWe the level of signal from the input of pressure control is active Tset...

Страница 24: ...atus of the digital outputs from DOUT0 up to DOUT5 AIN TO 0000 Screen INPUTS OUTPUTS 2 3 AIN status of the analogue input 0 10V TO status of the outputs of impulses T1 T4 Tb 25 5 0 C StanZas 24 OK Scr...

Страница 25: ...uts are relay outputs DOUT0 separable output of the control system of the fan contactor DOUT1 switchable output collective signal of the alarm DOUT2 switchable output indication of the fan work DOUT3...

Страница 26: ...lighting pulsatively The alarm has to be confir med with the button S2 STOP The alarm causes blockage of the system until the alarm dis appears After the alarm reason has vanished press the S2 STOP on...

Страница 27: ...cartridge correct functioning of the device filter 2 Dust is emerging outside The cartridge filter has got Replace the faulty cartridge the appliance defective or released untight filter or correct i...

Страница 28: ...at is installed for this purpose at the bottom part of the tank 9 4 Electromagnetic valves The applied electromagnetic valves do not require current maintenance It is sufficient to check the state of...

Страница 29: ...hould be carried out after the fan is switched off and the device is disconnected from the power supply system The fan as a rotary appliance constitutes a potential source of hazard therefore installi...

Страница 30: ...Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign requireme...

Страница 31: ...31 24 05 2019 Filtering unit UFO A 5000 NOTES...

Страница 32: ...24 05 2019 Producer KLIMAWENT S A 81 571 Gdynia ul Chwaszczy ska 194 tel 058 629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 804U17 UFO A 5000 RH 24 05 2019 EN 804U2...

Отзывы: