Klimawent BIG-5000/Ex Скачать руководство пользователя страница 3

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

08.10.2019

 

Filtering unit

 

BIG-5000/Ex

 

3 z 16 

 

BIG-5000-Ex filtering unit can be installed, exclusively in areas classified as 22, or in areas not featuring 
explosive hazard

.  

According to the ATEX 137 Directive, User has to determine the environment where 

the appliance shall be used

.

 

 

 

RESERVATIONS  OF  MANUFACTURER 

3.1    Manufacturer  is  not  responsible  for  damages  /  malfunctions  being  caused  as  a  result  of  reasons 
mentioned below

 

Any consequences following from the installing that is in contradiction to the present Use and Maintenance 
Manual. 

 

Situations  where  the  appliance  is  connected  to  the  electrical  power  supply-  or  the  pneumatic  system 
incorrectly. 

 

Operational use that is in contradiction with the present Use and Maintenance Manual and its specified 
purpose. 

 

Installing of any additional elements  that are not belonging  to the normal device structure (or accessory 
set) is not acceptable. 

 

Introduction of any structural or constructional modifications of the system on 

one’s own. 

 

Situations when the principles of control and maintenance of the appliance are not observed. 

 

Forwarding of the air containing viscous and aggressive impurities or of the air temperature exceeds 40

what might result in damage of the filters. 

 

3.2 

In the course of operational use, it is important to prevent ignition sources (i.e. sparks, cigarette 
butts / embers) from getting into the filtering unit. 

 

 

3.3 

Operator should wear antistatic clothes while emptying the waste container, during the technical 
inspection, maintenance and during any other activities near the filtering unit. 

 

 

3.4 

Do not use mobile phones and devices emitting  electromagnetic waves close to the filtering unit 
and in the vicinity. 

 

 

3.5 

At the side of decompression panel 

– it is important to create a hazard area of potential explosion 

according to the Fig. No.2.  This area should be free of barriers such as machines, devices, walls 
etc.  

 

 

3.6 

In  case  when  explosion  hazard  exists  within  the  whole  installation,  (where  the  filtering  unit  is 
installed),  User  should  carry  out  the  total  risk  evaluation,  with  reference  to  the  being  valid 
regulations and should apply protections of the filtering unit and the fan. 

 

 

TECHNICAL  DATA 

Table No.1 

Type 
 

Maximum 

volume flow 

Maxi- 

mum 

vacuum 

Motor 

rate 

Supply 

voltage 

Quantity of 

cartridge 

filters 

Acoustic    
pressure 

level 

Compressed 

air 

consumption 

Weight 

 

[m

³/h] 

[Pa] 

[kW] 

[V/Hz] 

[pcs] 

[dB(A)] 

[Nm

3

/h] 

[kg] 

BIG-5000/Ex 

7400 

3500 

7,5 

3x400/50 

74 

7,2* 

1075 

* Consumption of the compressed air is specified for the setting 0,2 second, whereas for the setting 0,5 second  
 

  

the air consumption will be 18 Nm

3

/h. 

Filtration efficiency 99,9% (according to the BIA classification) the filters carry the USGC class certificate. 
Cartridge filters:  quantity  6 pieces; 

diameter  

325 mm 

height  1200 mm 
total filtration area  87 m

2

 

 

Содержание BIG-5000/Ex

Страница 1: ...ION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND REPAIR 13 OCCUPATIONAL HEALTH AND SAFETY 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 15 DECLARATION OF CONFORM...

Страница 2: ...afety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gene...

Страница 3: ...tional use it is important to prevent ignition sources i e sparks cigarette butts embers from getting into the filtering unit 3 3 Operator should wear antistatic clothes while emptying the waste conta...

Страница 4: ...er They have been classified as zone 22 Fig No 2 Classification ATEX internal zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 5000 Ex filtering unit consists of three functional assemblies Regeneration...

Страница 5: ...ils described in separate Use and Maintenance Manual In Fig No 3 is illustrated the filtering unit along with the fan chamber Connection between these two units is an example as applied in the test st...

Страница 6: ...arge dimensions At the upper part of the regeneration chamber are installed lifting hooks for lifting and positioning during the transport and assembly activities After the chamber of filters is conne...

Страница 7: ...n sorts Any activities related to the installing necessarily must be performed by a specialised assembly team after being instructed Having completed the assembly check the conductivity between the su...

Страница 8: ...ned to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system consists of subsequent assemblies switc...

Страница 9: ...Q1M motor protective switch F1 F2 overcurrent disconnectors T1 transformer K1 electromagnetic relay K1T K2T time relays K1M contactor PT resistance relay Fig No 10 Switchgear A1 control unit Fig No 1...

Страница 10: ...from dP not active 0 01 9 99 kPa F13 control with the regeneration process 0 via contact 1 by readout from dP dP converter of the difference of pressures 7 2 1 Description of the displayed messages o...

Страница 11: ...of this function the display shows the dP readout and while the fan is stopped or the pipe conduits are not connected if the dP readout does not have the value 0 00 kPa this can be adjusted with pushb...

Страница 12: ...the door of the switchgear A1 When the alarm occurs it is important to disconnect the power supply by means of the S1 disconnector Next find the fai lure damage find out its their reason and remove t...

Страница 13: ...Dust emerges outside the devi The cartridge filter is not tightly con Replace the cartridge filter or ce nected of damaged improve its mounting The dust is of another sort than stated Contact the manu...

Страница 14: ...system During these activities it is important to wear antistatic clothes While emptying the waste container of the dust during the dismantling of the container and its mounting the waste container mu...

Страница 15: ...d device is indicated in the Card of Warranty The warranty does not comprise mechanical damage and malfunctions caused by User device failures caused during the use which is in contradiction with the...

Страница 16: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in potent...

Отзывы: