Filtering unit

 

BIG-5000/Ex

 

11 z 16 

 

 

B8a 

short-circuit protection of every single output 

if short-circuit occurs 

– the output will be automatically ignored – the relay of the K micro-controller, (in 

the normal mode 

– active), will be disable; whereby, the contact opens; 

the display shows alternatively:  code 

E1

 and the number of the faulty output; 

press the pushbutton 

B

 

– to reset the ALARM; 

B10 

manual activation of every single output 

– on the keyboard 

using the keyboard 

– it is possible to activate (manually and intermediately) every single output  – to 

carry out the test of function;  press the pushbutton 

– to select the requested output for activation; 

press the pushbutton 

C

 to activate the output; 

C0 

numeric input 

– activated form the keyboard 

in the 

set-up

 it is possible to activate or disable the control with any inputs of the device; if the inputs 

are disabled 

– it can be assumed that the inputs are continuously closed; 

C1d 

numeric control of the pressure control 

(

pressostat

is inactive

 

if the 

dP

 control is active (setting 

F07

– the cleaning cycles are switching ON and OFF – depending on 

the readout from the 

dP

During the 

dP

 readout and below the 

STOP

 threshold 

– the cleaning process stops – and the display 

shows alternatively:  

dP

  and the letter 

P

;  

During the 

dP

 readout and above the 

STOP

 threshold 

– the cleaning process starts;

 

C3 

readout  of  the  pressure  control 

(

pressostat

from  the  internal  converter 

–  maximum  10  kPa 

(

disabled

);

 

C7d1 

the contact of ALARM of maximum pressure difference 

– is open – upon the restart of the ALARM 

automation 

(

disabled

); 

if the 

dP

 readout is above the 

setup 

threshold 

– the maximum value of 

dP 

ALARM will be activated; 

Display shows the code of ALARM condition 

E7

 (see the description of alarm)  

or shows alternatively 

– 

dP

 readout 

– and the letter 

H

, according to the model; 

Adequate relay of the alarm indicated its condition. 
The alarm will automatically undergo to reset 

– if the 

dP

 readout is again below the alarm threshold; 

Activation of the alarm is delayed by 20seconds 

– after the default settings; 

C8 

setting of ZERO point of the dP 

(

disabled

this function enables the setting the ZERO point of the readout of the pressure control (pressostat);  
in case of this function:  the display shows the 

dP

 readout, and (while the fan is stopped; or the pipe 

conduits are not connected) 

– if the 

dP

 readout does not have the value 

0.00 kPa

, this can be adjusted 

with pushbuttons 

A

 and 

C

 

C13_10  full range of dP 

– 10 kPa

 

maximum value of the pressure difference (measured by the converter) is 

10.00 kPa = 100.0 mbar =  

1012 mmH

2

O

During the 

dP

 readout, where the value is above 

10 kPa

 

– the display shoes ‘

E

’ – instead of the numeric 

value of 

dP

D1ab1 

additional cycles 

– after the fan is stopped – in case of the selection of the fan mode

in the settings can be selected mode 

– to control the function of the regeneration run – connected with 

the function of the fan and with the cycles of final regeneration; 
SETTING = 0 (not obtainable in case of option 

C11a

); 

When  is  connected  a  non-potential  supporting  contact  (of  the  circuit  that  operates  the  fan  from  the 

micro-controller

), it is possible to add a number 

previously adjusted

 = that means a number of cycles 

of cleaning 

– after the fan is stopped.  

Their number is adjusted from the keyboard within the range from 

0

 up to 

99

Cycles of final regeneration 

– additionally, can be activated, when the 

dP value = 0

(inactive) 
If the 

D1a contact

 is open 

– the display with show alternatively:  ‘

-0-

’ and the 

dP readout

 

– to indicate 

that cycles do not proceed, because the fan is switched off; 
Decimal points on the display with emerge and vanish 

– during the cycle – after the fan is switched off; 

Caution D1a

:  Connect the 

D1a 

via bridge 

– if it is not used upon activated inputs (see 

F01 = 1

). 

 

If  the 

dP 

control  is  activated 

– it is possible to add the previously adjusted number of cycles of final 

regeneration. 
Their quantity can be adjusted form the keyboard within the range 

0

 up to 

99

The timer will compare the 

dP

 readout with the established threshold 

0.20 kPa

If the 

dP

 readout drops below 

0.20 kPa

 additional cleaning cycles will switch on, in case when the 

dP

 

readout will reach the value of 

STOP

 threshold 

– during normal function. 

In case when 

dP < 0.20 kPa

 the display will alternatively show: 

-0-

’ and the 

dP

 readout (disabled).

 

D6 

ON / OFF switch of the cleaning cycle 

– from external contact

 

If the 

D6

 contact is open 

– the cleaning cycle is not accessible – and the display will alternatively show: 

OFF

’ and the 

dP

 readout.  After the D6 contact is closed, the cleaning cycle can be operated from the  

electromagnetic valve. 
 

Caution D6

Apply the bridge for 

D6

 

– if this is not active for the activated outputs (see 

F01

Содержание BIG-5000/Ex

Страница 1: ...ION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND REPAIR 13 OCCUPATIONAL HEALTH AND SAFETY 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 15 DECLARATION OF CONFORM...

Страница 2: ...afety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gene...

Страница 3: ...tional use it is important to prevent ignition sources i e sparks cigarette butts embers from getting into the filtering unit 3 3 Operator should wear antistatic clothes while emptying the waste conta...

Страница 4: ...er They have been classified as zone 22 Fig No 2 Classification ATEX internal zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 5000 Ex filtering unit consists of three functional assemblies Regeneration...

Страница 5: ...ils described in separate Use and Maintenance Manual In Fig No 3 is illustrated the filtering unit along with the fan chamber Connection between these two units is an example as applied in the test st...

Страница 6: ...arge dimensions At the upper part of the regeneration chamber are installed lifting hooks for lifting and positioning during the transport and assembly activities After the chamber of filters is conne...

Страница 7: ...n sorts Any activities related to the installing necessarily must be performed by a specialised assembly team after being instructed Having completed the assembly check the conductivity between the su...

Страница 8: ...ned to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system consists of subsequent assemblies switc...

Страница 9: ...Q1M motor protective switch F1 F2 overcurrent disconnectors T1 transformer K1 electromagnetic relay K1T K2T time relays K1M contactor PT resistance relay Fig No 10 Switchgear A1 control unit Fig No 1...

Страница 10: ...from dP not active 0 01 9 99 kPa F13 control with the regeneration process 0 via contact 1 by readout from dP dP converter of the difference of pressures 7 2 1 Description of the displayed messages o...

Страница 11: ...of this function the display shows the dP readout and while the fan is stopped or the pipe conduits are not connected if the dP readout does not have the value 0 00 kPa this can be adjusted with pushb...

Страница 12: ...the door of the switchgear A1 When the alarm occurs it is important to disconnect the power supply by means of the S1 disconnector Next find the fai lure damage find out its their reason and remove t...

Страница 13: ...Dust emerges outside the devi The cartridge filter is not tightly con Replace the cartridge filter or ce nected of damaged improve its mounting The dust is of another sort than stated Contact the manu...

Страница 14: ...system During these activities it is important to wear antistatic clothes While emptying the waste container of the dust during the dismantling of the container and its mounting the waste container mu...

Страница 15: ...d device is indicated in the Card of Warranty The warranty does not comprise mechanical damage and malfunctions caused by User device failures caused during the use which is in contradiction with the...

Страница 16: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in potent...

Отзывы: