Filtering unit BIG-1000
02.03.2021
Original manufacturer settings
Process parameters:
Air valve opening time –
T1 =
0.5 sec
Time (interval) between air pulses –
T2 = 4 min
Pressure switch pressure setting –
B1 = 2000 Pa
! CAUTION
DO NOT
change the set point of the operating parameters! In case of required correction
of these parameters, contact the manufacturer
KLIMAWENT S.A.
ALARMS
The electric unit is equipped with the
H3
light signalling excessive dirtiness of the filter. The pressure switch
installed inside the device controls the airflow resistance through the filter and in case of excessive flow resistance
it activates the alarm on the control panel in the form of yellow
H3
light.
When the
H3
alarm appears, remove the filter from the unit and clean the filter manually or mechanically using
a device designed for this purpose – see 7.4 and 9.1.2.
After cleaning or replacing the filter with a new one, the
H3
light turns off.
CHANGE FILTER
To replace the filter, do the following:
A.
Open the inspection door.
B.
Remove the filter from its socket by turning the filter counterclockwise. Rotate the filter smoothly,
without jerking the filter pleats.
C.
Insert the clean filter into the slot by turning it in the opposite direction. Rotate the filter smoothly,
without jerking the pleats, until you feel resistance.
D.
Close the inspection door.
When replacing the filter, check its condition, i.e. the condition of the surface of the filter paper, seal, etc.– see
9.1.2 – Guidelines for cartridge filters.
EMPTYING THE COLLECTIVE CONTAINER
The dust container is attached with clamps. Open the clamps and empty the tank.
Be careful when emptying. Always use
personal protective equipment
when emptying the tank, cleaning it
from sediments, inspection.
! CAUTION – Dusty atmosphere!
Wear
eye protectors during service at the device!
Wear
a dust mask when servicing the equipment!