background image

5

ELECTRICAL SPECIFICATIONS

OTHER MEASUREMENT APPLICATIONS

Maximum Input:

 1000V RMS in Voltage setting, 

                           600V DC or 600V AC RMS in all other settings

• 

Diode Test: 

1.5 mA max, open circuit voltage 3.2V DC 

• 

Continuity Check: 

Audible signal when resistance <50Ω 

• 

Low Impedence (Low Z): 

Input impedence >3kΩ

 

        Max input 600V RMS

• 

Auto Power Off:

 After ~5 minutes of inactivity

• 

Sampling Frequency: 

3 samples per second

• 

Overload:

 "OL" indicated on display, 1000V RMS in voltage 

             settings, 600V RMS in all other settings

• 

Polarity: 

"-" on display indicates negative polarity

• 

Display: 

3-5/6 digit, 6000 Count Reverse Contrast Display,  

 

 

TRMS technology

 WARNINGS 

To ensure safe operation and service of the meter, follow these 

instructions. Failure to observe these warnings can result in 

severe injury or death.

•  Before each use verify meter operation by measuring a known 

voltage or current.

•  Never use the meter on a circuit with voltages that exceed the 

category based rating of this meter.

•  Do not use the meter during electrical storms or in wet weather.

•  Do not use the meter or test leads if they appear to be damaged.

•  Use only with CAT IV rated test leads.

•  Ensure meter leads are fully seated, and keep fingers away 

from the metal probe contacts when making measurements.

•  Do not open the meter to replace batteries while the probes 

are connected.

•  Use caution when working with voltages above 25V AC RMS 

or 60V DC. Such voltages pose a shock hazard.

•  To avoid false readings that can lead to electrical shock, 

replace batteries when a low battery indicator appears.

•  Do not attempt to measure resistance or continuity on a live 

circuit.

•  Always adhere to local and national safety codes. Use personal 

protective equipment to prevent shock and arc blast injury 

where hazardous live conductors are exposed.

•  Meter is IP42 dust & water resistant. Following any contact 

with water, thoroughly dry meter and test lead jacks prior to 

subsequent use.

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Содержание 092644693762

Страница 1: ...LOW IMPEDANCE AUDIBLE CONTINUITY MIN MAX RELATIVE TEMPERATURE DIODE TEST CAPACITANCE FREQUENCY Auto Ranging Digital Multimeter True RMS Measurement Technology MM720 2m IP42 CAT IV 600V CAT III 1000V 5...

Страница 2: ...3 85 7 47 7 mm Weight 12 2 oz 345 g Calibration Accurate for one year Standards Conforms to UL STD 61010 1 61010 2 030 61010 2 033 Certified to CSA STD C22 2 61010 1 61010 2 030 61010 2 033 EC EN 6101...

Страница 3: ...A 0 1 A 1 0 5 digits 6000 A 1 A 60 00mA 10 A 600 0mA 100 A 6 000A 1mA 2 0 3 digits 10 00A 0 01A 2 0 5 digits DC Current A and mA 600 0 A 0 1 A 1 0 3 digits 6000 A 1 A 60 00mA 10 A 600 0mA 100 A 6 000...

Страница 4: ...its 99 99Hz 0 01Hz 999 9Hz 0 1Hz 9 999kHz 1Hz 99 99kHz 10Hz 500 0kHz 100Hz Voltage Range 2V to 220V RMS Maximum Input 600V DC or 600V AC RMS DUTY CYCLE 1 0 to 99 9 0 1 1 2 2 digits Pulse Width 0 1 100...

Страница 5: ...uit with voltages that exceed the category based rating of this meter Do not use the meter during electrical storms or in wet weather Do not use the meter or test leads if they appear to be damaged Us...

Страница 6: ...ectrical Shock Improper use of this meter can lead to risk of electrical shock Follow all warnings and instructions detailed in this manual ENGLISH SYMBOLS ON LCD H Data Hold Audible Continuity Diode...

Страница 7: ...er 1 6000 count Reverse Contrast Display 7 RANGE button 2 Function selector switch 8 REL Relative button 3 10A jack 9 MAX MIN button 4 COM jack 10 HOLD Backlight button 5 V jack 11 SEL Select button 6...

Страница 8: ...meter in white the secondary functions are printed on the meter in orange HOLD DATA HOLD BACKLIGHT BUTTON Press HOLD 10 to hold the measurement on the display Press again to release the display to ret...

Страница 9: ...ON When the MAX MIN button 9 is pressed the meter keeps track of the minimum and maximum value of the measurement as the meter continues to take samples 1 When measuring press MAX MIN 9 and the meter...

Страница 10: ...ENT LOCATIONS Ensure the test lead shield is pressed firmly in place Failure to use the CAT III CAT IV shield increases arc flash risk TESTING IN CAT II MEASUREMENT LOCATIONS CAT III CAT IV shields ma...

Страница 11: ...TE If appears on the LCD the test leads are being applied to the circuit in reverse Swap the position of the leads to correct this NOTE When in a voltage setting and the test leads are open readings o...

Страница 12: ...rt RED test lead into 10A jack 3 and BLACK test lead into COM jack 4 and rotate function selector switch 2 to the 10A AC DC setting For mA AC DC currents 600mA Insert RED test lead into mA A jack 6 an...

Страница 13: ...utton 11 until the icon appears 2 Remove power from circuit 3 Test for continuity by connecting conductor or circuit with test leads If resistance is measured less than 50 an audible signal will sound...

Страница 14: ...otate function selector switch 2 to the Continuity Resistance Diode Capacitance setting NOTE The meter defaults to Continuity testing in this mode To enter Diode testing mode press the SEL button 11 t...

Страница 15: ...est leads across the capacitor The meter will auto range to display the measurement in the most appropriate range FREQUENCY DUTY CYCLE 1 Insert RED test lead into V jack 5 and BLACK test lead into COM...

Страница 16: ...e make contact between the thermocouple tip and the object being measured When thermocouple tip and object are in thermal equilibrium the measurement on the display will stabilize The meter will auto...

Страница 17: ...move screw from battery fuse door 2 Replace blown fuse s with A mA jack 6 800mA 1000V fast blow Klein Cat No 69390 10A jack 3 10A 1000V fast blow Klein Cat No 69034 3 Replace battery fuse door and fas...

Страница 18: ...ts mentioned in the General Specifications section allow the meter to return to normal operating conditions before using FCC IC COMPLIANCE See this product s page at for FCC compliance information Can...

Отзывы: