17
MAINTENANCE
BATTERY REPLACEMENT
When the
indicator is displayed, the batteries must be replaced.
1. Remove screw from battery/fuse door.
2. Replace 2 x AAA batteries (note proper polarity).
3. Replace battery/fuse door and fasten securely with screw.
FUSE REPLACEMENT
A fuse may blow if more than 800mA is applied to the μA/mA jack
6
,
or more than 10A is applied to the 10A jack
3
. To access fuses:
1. Remove screw from battery/fuse door.
2. Replace blown fuse(s) with:
μA/mA jack
6
:
800mA/1000V fast-blow (Klein Cat. No. 69390)
10A jack
3
:
10A/1000V fast-blow (Klein Cat. No. 69034)
3. Replace battery/fuse door and fasten securely with screw.
To avoid risk of electric shock, disconnect leads from any voltage
source before removing battery/fuse door.
To avoid risk of electric shock, do not operate meter while
battery/fuse door is removed.
2× AAA batteries
800mA/1000V fast-blow fuse
(Klein Cat. No. 69390)
10A/1000V fast-blow fuse
(Klein Cat. No. 69034)
www.calcert.com
1.800.544.2843
0
5
10
15
20
25
30