Page 42 of 72
Error
Cause of error / error rectification
"Gate closed
limit switch"
flashes red
Unplug all gate power cables and check whether a pin has moved backwards. Also check this
with the socket connector plugs.
Check on all dead boxes to see whether a pin has moved backwards. Also check this with the
socket connector plugs.
Signal "Gates
closed" not
present
(sliding
gates)
Check whether the closure plug is plugged in on the last gate box.
For vertical gates:
closure plug with orange sleeve
For sliding gates:
closure plug without orange sleeve
Unplug all gate power cables and check whether a pin has moved backwards. Also check this
with the socket connector plugs.
Check on all dead boxes to see whether a pin has moved backwards. Also check this with the
socket connector plugs.
"Gate locked" limit switch is faulty. Check, by measuring the contacts.
There is such a switch on every sliding gate. Check and if req. replace all switches.