Sheet Metal Thickness / Double Sheet Detection BDK-1.3, BDK/FS-, …/FP-, …/PN-, …/OB-1.3
Series Universal Double Sheet Metal Monitor
Ref. no. 20.05-80, ...-81, ...-82, ...-93, 20.21-01
© Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: [email protected] • www.klaschka.de
KLASCHKA
GB 5.17
BDK 27/29
17. Technical Data
17.1. Evaluation Devices
Inputs
Start external (STA)
- lo-level
1 ... 8 VDC
- hi-level
12 ... 30 VDC
- Lead break detection
0 ... 1 VDC
(external resistor neces-
sary, see page 19)
- Input current
approx. 10 mA
- Electrical isolation
yes (to power supply)
Threshold select external
(A1 ... A8 and Relays reset)
- lo-level
0 ... 4 VDC
- hi-level
12 ... 30 VDC
- Input current
approx. 10 mA
- Electrical isolation
yes (to power supply)
Outputs
Elektromechanical relays
- Relay output K0
1 NC, 1 NO
- Relay outputs K1, K2
1 rev. switch each
6 A, 250 VAC
Semi-conductor relays
*)
- Relay output K0
1 NC, 1 NO
- Relay outputs K1, K2
1 rev. switch each
0.5 A, 30 V
Measurement accuracy
- At calibration point
±
0.1 or. 0.2 mm
- Across measurement range
±
5% end-of-scale
value
- Permissible air gap
see page 22
Power supply
DC voltage
24 VDC
- Tolerance
±
15%
- Residual ripple
max. 10%
Power consumption
- During measurement
max. 100 VA (when mea-
sured with DSP and
DSPW sensors, otherw.
20 VA)
- Idle state
approx. 12 VA
Overload protection
via fuses
- At 24 VDC
t 3.15 A
Housing
sturdy metal housing,
lockable cover with
window
- Protection rating
IP 65
- Mounting
screw mounting (4 x M6)
Weight
approx. 3.5 kg
Ambient temperature
0 ... 55 °C
*)
When connecting inductive loads to the semi-conductor
relays, an appropriate cut-off protection has to be used.
17.2. DSP Sheet Metal Thickness Sensor
Workpiece
ferromagnetic sheets
Field coil
- Nominal voltage
approx. 38 VDC
- Coil current
max. 2.2 A
Proximity switch
- Type
IAD-m8rg-2k
- Switching distance
approx. 1.2 mm
Housing material
nickel-plated steel
Protection rating
IP 65
Ambient temperature
0 ... 60 °C
17.3. BDWF Sheet Metal Thickness Sensor
Workpiece
non-ferrous sheets
Power supply
24 VDC
Input current
10 Vpp
Sheet detection
- Switching distance
1 ... 5 mm (dep. on sheet)
Housing material
nickel-plated steel
Protection rating
IP 65
Ambient temperature
0 ... 60 °C
17.4. BDWD/S, BDWD/E T Sheet Thickness
Sensors
Workpiece
ferrous and non-ferrous
sheets
Power supply
24 VDC
Input current
10 Vpp
Housing material
nickel-plated steel
Protection rating
IP 65
Ambient temperature
0 ... 60 °C
17.5. DSD Sheet Metal Thickness Sensor
Workpiece
ferromagnetic sheets
Power supply
24 VDC
Housing material
nickel-plated brass
Protection rating
IP 65
Ambient temperature
0 ... 60 °C
17.6. DSPW Sheet Metal Thickness Sensor
Workpiece
ferroumagnetic sheets,
non-ferrous sheet
Power supply
24 VDC
Sheet detection
- Switching distance
1 ... 5 mm
Housing material
nickel-plated steel
Protection rating
IP 65
Ambient temperature
0 ... 60 °C
17.7. Standards Applied
Measuring relays and protection equipment EN 60255-1
EMC emission
EN 61000-6-4
EMC immunity
EN 61000-6-2
Содержание BDK-1.3
Страница 2: ......