49
Table 1.0 Command ID
Data Byte
Data Type
Byte details
7 ------- 0
Data Details
$0c (12) = Not Used
00000000
$0d (13) = Not Used
00000000
$0e (14) = Pattern Level Hi
000xxxxx
$0f (15) = Pattern Level Lo
0yyyyyyy
Hi & Lo are combined to make single 12 bit command.
00 0yyyyyyy = 0000xxxx xyyyyyyy
$10 (16) = Pattern Control
00000xyz
y =
VCA Amount Destination - 0=Off 1=On
z =
VCF Cutoff Destination - 0=Off 1=On
x =
Clock Source – 0=Arp 1=Seq
$11 (17) = Int Clock Rate Hi
0000xxxx
$12 (18) = Int Clock Rate Lo
0000yyyy
This byte is sent as two nibbles which are combined to
make single 8 bit command.
00 0000yyyy = xxxxyyyy
Range is 0-255 for 5-300 BPM
$13 (19) = MW Level
0xxxxxxx
x = Range $00-$7f (0-127)
$14 (20) = AT Level
0xxxxxxx
x = Range $00-$7f (0-127)
$15 (21) = Key Trans Disable
0000000x
x = Disable Key Transpose (0=enable,1=disable)
$16 (22) = Display Mode
000000yz
z =
Clock Display - 0=Off 1=On
y =
Scrolling Display - 0=Off 1=On
$17 (23) = Memory Protect
0000000z
z =
Memory Protect - 0=Protected 1=Not Protected
Note – This is read only and can only be changed by the
Memory Protect Switch on the rear of the Juno-106
$18 (24) = Not Used
00000000
$19 (25) = Internal Tune
0xxxxxxx
x =
Fine Tune Override
0 = use Fine tune on rear of 106
1-127 = Override fine tune
Note – When the fine tune is being overridden changing
the rear tune knob will override this setting
$1a (26) = External Pedal
Polarity
0000000x
x =
Ext Pedal Polarity
0 = Normal Polarity (N/O)
1 = Reverse Polarity (N/C)
$1b-$1f (27-31) = Nulls
Not currently Used
$03 (3) Request Patch Edit Buffer
Dump
No Data
www.kiwitechnics.com
Kiwi-106 Upgrade User Manual v204