12
Routine maintenance reminders
It is forbidden to remove the safety covers and devices in order to carry out routine
maintenance operations. Both routine and non-routine maintenance must be carried out by a qualified
technician in compliance with the manufacturer's instructions and current regulations in the country of
installation.
The manufacturer declines all liability for accidents resulting from the non-observance of this requirement.
Disconnect the power supply before any maintenance work (press the ON/OFF button
on the right hand side of the machine).
CLEANING THE EXTERNAL SURFACES
Body
Clean the external surfaces of the vacuum packing machine, which are made of stainless steel, with a soft
cloth or sponge and neutral detergent, wiping in the direction of the grain of the satin finish.
Do not use steel scouring pads, scrapers or any abrasive, acidic or aggressive substances which could
damage the stainless steel surfaces irreparably.
IMPORTANT
During cleaning do NOT remove the data plate as this provides important information on
the machine for the after-sales service.
Control panel
The machine's control panel has touch control buttons, which are totally flush to the machine for ease of
cleaning, to be carried out with a proprietary glass cleaner.
Use a soft cloth with a little detergent and dry thoroughly afterwards.
CLEANING THE VACUUM CHAMBER
In order to ensure hygiene and safeguard the quality of foodstuffs packed, the vacuum chamber must be
cleaned after each use.
The design of the chamber facilitates quick, easy cleaning. Use a soft cloth or non-abrasive sponge and
neutral detergent or an alcohol-based disinfectant.
CLEANING THE GLASS LID
Likewise, clean the glass lid after every use.
Use a soft cloth or non-abrasive sponge dampened with potable water, or else a proprietary glass cleaner.
CLEANNG THE SEALING BAR
Once a month, clean the sealing bar in order to
remove any residue which could negatively impact the
quality of bag sealing.
To facilitate this procedure, lift the sealing bar (
A
) up,
removing it from the two pins (
B
).
Use a soft cloth or non-abrasive sponge and neutral
detergent or an alcohol-based disinfectant.
After cleaning, fit the bar on the pins (
B
), lining up the
two holes on the underside of the bar and make sure
it engages securely.
IMPORTANT
Do not remove the black teflon tape.