11
Machine operation indications
Switching On (pulling the drawer out to working position)
Always pull the drawer out to its full extension so that the
glass lid can open fully.
Switch the machine on using the blue On switch on the front
right hand side.
The control panel
leds
light up and a brief acoustic signal
indicates the machine has been switched on. At this point the
machine runs a
set-up cycle
lasting approximately 2 seconds; do
not press any buttons until set-up has been completed.
Vacuum Cycle for Bags
At the start of each cycle, a brief acoustic signal is emitted.
The cycle automatically proceeds as follows:
• The air
extraction phase
is indicated by the flashing of the
function button. This phase lasts approximately 2 minutes
and 30 seconds.
• The heat
sealing phase
is indicated by the function button led
remaining lit. This phase lasts 9 seconds. This is followed by
a cooling phase lasting approx. 5 seconds.
• During the subsequent
exhaust phase
all the led indicators
return to their initial state. The exhaust valve remains open
for 20 seconds.
During this time, no function can be selected.
• Once the vacuum chamber is decompressed, the lid can be opened and the sealed bag removed.
• At the end of the cycle, a brief acoustic signal is emitted, indicating that the machine is ready to perform
another cycle.
• The total duration of the cycle is 3 minutes (to reopening of the glass lid)
IMPORTANT
The cycle can be stopped in advance by pressing the button
. In this case, the machine
will not proceed with sealing and the chamber will be decompressed. Wait for approximately 20 seconds
and the acoustic signal before starting another cycle.
Vacuum cycle for KitchenAid containers
At the start of each cycle, a brief acoustic signal is emitted.
The cycle automatically proceeds as follows:
• The
vacuum phase
is indicated by the function button led flashing. This phase lasts approximately 45
seconds.
• During the subsequent
exhaust phase
all the led indicators return to their initial state. The exhaust valve
remains open for 20 seconds.
During this time, no function can be selected.
• Once the vacuum chamber is decompressed, the lid can be opened and the vacuum container
removed.
• At the end of the cycle, a brief acoustic signal is emitted, indicating that the machine is ready to perform
another cycle. The chamber is decompressed, enabling the container to be removed.
• The total duration of the cycle is 1 minute (to reopening of the glass lid)
IMPORTANT
The cycle can be stopped in advance by pressing the button
. The chamber is
decompressed and the glass lid will lift. Wait for approximately 20 seconds and the acoustic signal before
starting another cycle.
Содержание KSVC 3610
Страница 1: ...Instructions for use ...
Страница 2: ......
Страница 19: ......
Страница 20: ...5019 744 02024 A GB Printed in Italy n 03 12 ...