Installation 

THIS OPERATION MUST BE PERFROMED BY 

QUALIFIED TECHNICIAN OR AUTHORISED 
PERSON. 

Technical information for the installer  
• This appliance can be built into a 30mm to 

70mm thick worktop. 

•  If no oven is to be installed below the hob, a 

panel must be fitted under the hob to 
prevent hob damage and protect the 
cupboard contents. This panel must cover 
the whole of the underside of the hob and 
must be positioned so that an air gap of at 
least 15mm between the panel and hob 
underside is maintained, as a minimum, and 
as a maximum 150mm to the underneath of 
the work surface. 

•  This hob is designed to operate perfectly 

with any oven in the KitchenAid range. The 
Manufacturer declines all responsibility 
should any other make of oven be installed.  

The manufacturer declines all responsibility 

should another make of oven be installed.

 

 

Before installation, please ensure that: 

  Warning: this is a heavy product which 

requires the installation to be carried out 
by two people.

 

•  The gas supply (type and pressure) and the 

calibration on the hob are compatible (see 
serial number plate on the hob and the table 
on page 7). 

 

NOTE: as per AS/NZS 5601.1 gas appliance 

shall be installed in such a way that surface 
temperature of any nearby surface will not 
exceed 65 Deg. C above ambient. 

 

PLEASE NOTE GAS REGULATRO PACKED WITH 

THIS APPLIACNE IS ONLY SUITABLE FOR 
CONNECTION TO NATURAL GAS.

 

•  The cabinetry and appliances surrounding/next to 

the hob are heat resistant and in compliance with 
local regulations.  

•  The products of combustion are removed from the 

atmosphere in the room by using an extraction 
hood or electrical fan installed to the walls and or 
windows, in line with current regulations.   

•  The air circulates naturally through a suitable 

opening that is no less than 100cm2 in cross 
section, which must be:  

-  Permanent and accessible on the walls of the 

room being ventilated and extracting towards the 
outside.  

-  created in such a way that the openings both 

inside and out cannot be obstructed, even in error.  

-  Protected by plastic grill, metallic netting etc. that 

should not reduce the 100cm2 cross section 

 - Located in such a position so as not to interfere 

with the extraction of the products of combustion. 

-Connection from one type of gas to another should 

be only performed by qualified technician or 
approved gas fitter. 

 

This appliance shall be installed in accordance with 

installation requirements of AS/NZS 5601 current 
edition). 

 

IMPORTANT: if flexible hose is used, it must be 

installed in such a way that does not come into 
the contact with the drawers or any other mobile 
kitchen parts. The hose must be installed in such 
a way that is easy to visually inspect without 
obstructions 

 

Hose assembly used with cooking appliances shall 

be certified as conforming to AS/NZS 1869 and be 
class B or class D. 

 
 

 
 
 

 

Содержание KHDD2 38510

Страница 1: ...www kitchenaid com au www kitchenaid co nz Page 1 AU Instructions for Use ...

Страница 2: ...www kitchenaid com au www kitchenaid co nz Page 2 ...

Страница 3: ...es mm 6 Gas Consumption and Injectors table 7 Warnings and Suggestions 7 Safeguarding the Environment 8 Installation 9 Gas connection 10 Electrical Connection 11 Installation 12 Adaption to a different type of gas supply 12 Replacing the injectors 13 Regulating the minimum flow level of the gas taps 13 Care and Maintenance 14 Care and maintenance of the gas burners 14 Troubleshooting guide 15 Afte...

Страница 4: ...ner 3 Once the burner has lit keep the control knob pressed for about 5 seconds to allow the safety thermocouple fitted to each burner to engage The thermocouple will switch off the gas supply to the burner should the flame be accidentally lost A gust of air momentary interruption of gas supply or liquid spillage etc If the burner does not ignite within about 15 seconds switch off the burner check...

Страница 5: ...cotta dishes on the hob as this may damage the pan supports Convectors such as metal netting or others The use of two burners simultaneously with just one container such as a fish kettle Important Do not rest or drag the pan supports upside down on the hob as this could scratch it Failure to comply with these recommendations could lead to the glass ceramic hob being damaged or broken and the safet...

Страница 6: ...and a range hood or an exhaust fan overhead clearance shall not be less than 60 mm for a range hood and not less than 750 for an exhaust fan NOTE In case of installation of a hood above the cook top please refer to the range hood instructions for the correct distance NOTE Indicated clearance dimensions are applicable to non combustible materials If needing to install multiple Domino products in th...

Страница 7: ...ion and remove all protective packing and films before installation This hob cat 3 was designed to be used exclusively for cooking food in household surroundings Any other use for example heating rooms should be regarded as improper and dangerous The installation and connection of this appliance to a gas or electrical supply must be carried out by a competent qualified person in compliance with cu...

Страница 8: ...inder Do not obstruct the air vents at the back of the appliance in any way DO NOT USE OR STORE FLAMMABLE MATERIALS IN THE APPLIANCE STORAGE DRAWER OR NEAR THIS APPLIANCE DO NOT SPRAY AEROSOLES IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION DO NOT MODIFY THIS APPLIANCE WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR IN A CARAVANS IT SHALL NOT BE USED A SPACE HEATER Safeguarding th...

Страница 9: ...t PLEASE NOTE GAS REGULATRO PACKED WITH THIS APPLIACNE IS ONLY SUITABLE FOR CONNECTION TO NATURAL GAS The cabinetry and appliances surrounding next to the hob are heat resistant and in compliance with local regulations The products of combustion are removed from the atmosphere in the room by using an extraction hood or electrical fan installed to the walls and or windows in line with current regul...

Страница 10: ...he regulator pressure for NG is 1 0 kPa For ULPG model the gas supply must be regulated to a pressure of 2 75 kPa The gas inlet connection fitting is 1 2 B S P male tread in compliance with ISO 7 1 thread A manual shut off valve must be installed in the gas line in an accessible position external tot the hotplate so in the event of emergency the gas supply can be shutoff For gas inlet position of ...

Страница 11: ... legislation and be carried out by a qualified competent person Information on the voltage and power absorbed are shown on the serial number plate The appliance must be earthed When installing the appliance we recommend that this hob is protected by a 3mm bi polar switch If damaged the power cable must be replaced with an identical type of power cable We recommend that this operation be conducted ...

Страница 12: ...of 90 C Adaption to a different type of gas supply If you are using a different kind of gas from the one indicated on the serial no plate and the orange label on the back of the hob you must replace the injectors in the case of the Wok burner adjust the primary air see Injector table on page 6 The orange label should be removed and kept together with the manual Use pressure regulators suitable for...

Страница 13: ... primary air in the burners To ensure the minimum level is properly regulated remove the control knob and adjust the screws found on the tap as follows 1 tighten to reduce the height of the flame 1 2 slacken to increase the height of the flame 3 With the burners on rotate the buttons from the maximum to the minimum position to check the stability of the flame NOTE Service and maintenance only to b...

Страница 14: ...d glass parts should be cleaned with warm water and or a neutral detergent Care and maintenance of the gas burners The pan supports and burners can be removed to make cleaning easier 1 Hand wash carefully in hot water with a mild detergent making sure that all the ingrained dirt is removed and the openings on the burner are not blocked The internal burner cap D on page 13 is made of brass and is s...

Страница 15: ...table Check that 1 the bottom of the pot is perfectly flat 2 the pot is centred on the burner 3 the pan supports are correctly positioned with all the rubber feet in place If despite all these checks and after tuning the hon off and on again you are still experiencing problems please contact our Customer Care Centre After Sales Service Before contacting our Customer Care Centre please check to see...

Страница 16: ...www kitchenaid com au www kitchenaid co nz Page 16 Printed in Italy 10 16 851321077167 ...

Отзывы: